Design and Simulation of Novel Gated Integrator for the Heavy ion Beam Monitors System
Journal Title: American Journal of Engineering and Applied Sciences - Year 2017, Vol 10, Issue 1
Abstract
Abstract In this study, the objective is to realize a Gated Integrator (GI) circuit for silicon strip, Si(Li), CdZnTe and CsI detectors etc. With the development of radioactive ion beam physics, heavy-charged particles like carbon ions have been applied to the treatment of deep-seated inoperable tumors in the therapy terminal of the Heavy ion Research Facility in Lanzhou (HIRFL) located at the Institute of Modern Physics (IMP), Chinese Academy of Sciences (CAS). A high resolution current measurement circuit was developed to monitor the beam current at 1pA range. The circuit consisted of a low current high sensitivity I/V converter and gated integrator in an energy spectroscopy. A low offset voltage precision amplifier and new guarding and shielding techniques were used in the I/V converter circuit which allowed to measure low current. This paper will show a MOS switch configuration which is used to prevent leakage current and novel technique to compensate a charge injection in the reset switch. Copyright © 2017 Djamet Yimga Arnaud, Wembe Tafo Evariste and Essimbi Zobo Bernard. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Authors and Affiliations
Djamet Yimga Arnaud, Wembe Tafo Evariste, Essimbi Zobo Bernard
Liquid Crystalline Polymers Compatibilization and Adhesion Enhancement by Reactive Blending in Post-Consumers PET’s
Abstract A method for PET mechanical properties enhancement by reactive blending with HBA/HNA Liquid Crystalline Polymers for in situ highly fibrillar composites preparation is presented. LCP/PET blends were reactive ex...
Present a Mechatronic System Having Able to Determine the Concentration of Carotenoids
Abstract Civilization besides its major advantages (undisputed) brought us some unhealthy habits which unfortunately have managed to penetrate deeply within several generations on the current planetary populations produ...
Performance Evaluation of an Assisting Device for Training "Normal-Like" Sit To Stand Movement
Performance Evaluation of an Assisting Device for Training "Normal-Like" Sit To Stand Movement Pierluigi Rea, Erika Ottaviano and Gianni Castelli DOI : 10.3844/ajeassp.2017.639.648 American Journal of Engineering and A...
Understanding Hybrid Additive Manufacturing of Functional Devices
Abstract The fabrication of electronic components in three-dimensional space is critical for building multifunctional devices. Traditional manufacturing approaches are limited to building planar device configurations. I...
Updating Italian Design Guide CNR DT-205/2007 in View of Recent Research Findings: Requirements for Pultruded FRP Profiles
Abstract A discussion on some design rules for pultruded fiber-reinforced plastic (PFRP) profiles reported by guideline CNR DT-205/2007 from National Research Council of Italy is presented in the paper. At eight years a...