Design of Chiller for Air Conditioning of Residential Building
Journal Title: International Journal of Trend in Scientific Research and Development - Year 2019, Vol 3, Issue 3
Abstract
The main objective of the project is to design and draft a fully functional Heating, Ventilation and Air Conditional HVAC system for computer center. From residential to commercial structures such as apartments, laboratories, hospitals, etc..., can be designed with HVAC components. HVAC is used to adjust the comfort level of both ambient temperature and air humidity to feel comfortable in enclosed spaces. As we want the heating, cooling, and ventilating system to perform well, we needed to start with an efficient duct design. In this project, we designed a duct system using the protocols based on ISHRAE Indian Society of Heating Refrigeration and Air conditioning Engineers and ASHRAE American Society of Heating Refrigeration and Air conditioning Engineers standards. The underlying principle was to design a duct system, which delivers the correct Cubic Feet per Minute CFM air flow to the residential building against the friction created by the ducts and fittings, with the static pressure available from the blower. When there is more surface area exposed to the air flow from the blower, amount of friction will increase and the blower must work more competently to achieve the required air flow. To provide greater air flow by overcoming the friction, radius elbow ducts are used, which provides smooth radius ensuring uniformity of air flow, reduces turbulence which in turn results in very low pressure drop. For Duct design calculations we used AUTO DESK REVIT design software. For space references and calculations, Autodesk Revit plan was taken from the civil department and the position of duct was identified. Based on the obtained Heat Load Calculations and cubic feet per minute are calculated by using E 20 form sheet and by using ISHRAE handbook, duct sizes were design and chiller size was estimated for residential building. by Srihari. M | Md. Irshad | K. Mahesh | K. Sai Teja "Design of Chiller for Air-Conditioning of Residential Building" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-3 , April 2019, URL: https://www.ijtsrd.com/papers/ijtsrd23291.pdf Paper URL: https://www.ijtsrd.com/engineering/mechanical-engineering/23291/design-of-chiller-for-air-conditioning-of-residential-building/srihari-m
Determination of Range of Splash of Testing Fluid during Hydro Testing of Knife Gate Valve
There are certain trivial experimental findings which may not have a major significance but their execution is considered to be of such a nature as to complete the study in the specified area. Likewise in the field of hy...
Design and Fabrication of Turning Fixture and Drilling Jig for Exhaust Manifold
The successful running of any mass production depends upon the interchangeability to facilitate easy assembly and reduction of unit cost. Mass production methods demand a fast and easy method of positioning work for accu...
A Study on Employee Safety and Welfare Measures with Special Reference to Cotton Industries in Coimbatore District
Safety and welfare measures are inevitable to any organization where workers are involved. An organization's Responsibility to its Employees extends beyond the payment of wages for their services. The Employer's Safety a...
A Comprehensive Review of Possibility using Solar Energy for Electricity Generation in Libya
Libya suffers from electricity shortages, and many challenges will have to be overcome to meet future increases in electrical demands. The deficiency of electricity generation in Libya is clearly manifested in the fact t...
Facial Authentication for Controlling Mouse Cursor with Hand Motion Detection using Webcam
In this paper, a human computer interface using hand gestures or any hand signal is introduced. This system is enhanced to replace the use of computer mouse with any hand signal instead of using any face expression. The...