Design of Multistoried R.C.C. Buildings with and without Shear Walls

Abstract

 From the past records of earthquake, there is increase in the demand of earthquake resisting building which can be fulfilled by providing the shear wall systems in the buildings. Static Analysis is performed for regular buildings up to 90m height in zone II and III, Dynamic Analysis should be performed for regular buildings in zone IV and V above 40 m. Reinforced cement concrete (RCC) framed structures combined with shear walls has been widely used to resist lateral forces during earthquakes in tall buildings. Shear walls are generally provided for full height of the frame. Shear wall systems are one of the most commonly used lateral-load resisting systems in high-rise buildings. Shear walls have very high in-plane stiffness and strength, which can be used to simultaneously resist large horizontal loads and support gravity loads, making them quite advantageous in many structural engineering applications. An earthquake load is applied to a building for G+12, G+25, G+38 located in zone II, zone III, zone IV and zone V for different cases of shear wall position. An analysis is performed using ETAB v 9.0.7 software. Lateral displacement and story drift are calculated in all the cases. It was observed that Multistoried R.C.C. Buildings with shear wall is economical as compared to without shear wall.

Authors and Affiliations

M. S. Aainawala 1 ,

Keywords

Related Articles

 Comparative Study of Test Prioritization Testing Technique

 Testing of software is an important means of assessing the software to determine its quality. Testing activities support quality assurance by gathering information about the nature of the software being studied. S...

 DISCRETE POPULATION GROWTH MODEL WITH CONSTANT FORCED REPRODUCTION AND CONSTANT HARVESTING

 A generalization of discrete logistic growth model is considered. Constant harvesting for human consumption of species is taken into account. At the same time, forced reproduction of the same species is also consi...

 Nonlinear Process Identification using Neural Networks

 In industry process control, the model identification of nonlinear systems are always difficult problems. The main aim of this paper is to establish a reliable model for the nonlinear process. In many applications...

 Optimal Placement of Multiple Distributed Generators in HVDC System for Performance Improvement

 Distributed generators are one of the important external sources in the power distribution system. Installing DGs at the optimum load centers will prevent the new transmission lines extension to energize substatio...

 RISK ASSESSMENT OF LEAD IN CHICKEN MEAT AND EGGS FROM DIFFERENT ENVIRONMENTS OF EGYPT

 Chickens are the most common sources of poultry meat (87%) of total poultry production. Heavy metals as lead are widely dispersed in the environment and may causing contamination of foods and health risks to consu...

Download PDF file
  • EP ID EP117056
  • DOI -
  • Views 103
  • Downloads 0

How To Cite

M. S. Aainawala 1, (30). Design of Multistoried R.C.C. Buildings with and without Shear Walls. International Journal of Engineering Sciences & Research Technology, 3(7), 498-510. https://europub.co.uk/articles/-A-117056