Abstract

 From the past records of earthquake, there is increase in the demand of earthquake resisting building which can be fulfilled by providing the shear wall systems in the buildings. Static Analysis is performed for regular buildings up to 90m height in zone II and III, Dynamic Analysis should be performed for regular buildings in zone IV and V above 40 m. Reinforced cement concrete (RCC) framed structures combined with shear walls has been widely used to resist lateral forces during earthquakes in tall buildings. Shear walls are generally provided for full height of the frame. Shear wall systems are one of the most commonly used lateral-load resisting systems in high-rise buildings. Shear walls have very high in-plane stiffness and strength, which can be used to simultaneously resist large horizontal loads and support gravity loads, making them quite advantageous in many structural engineering applications. An earthquake load is applied to a building for G+12, G+25, G+38 located in zone II, zone III, zone IV and zone V for different cases of shear wall position. An analysis is performed using ETAB v 9.0.7 software. Lateral displacement and story drift are calculated in all the cases. It was observed that Multistoried R.C.C. Buildings with shear wall is economical as compared to without shear wall.

Authors and Affiliations

M. S. Aainawala 1 ,

Keywords

Related Articles

A Study of Various Techniques of Preparing Magnetic Abrasives

With the development in the industries like Aeronautics, Optical Electronics, Medical instruments and Nuclear Reactors the need of part surface finish and geometric precision has increased drastically. The Magnetically...

 CFD ANALYSIS OF BLENDED WING BODY AND B2 WING

 In recent years unconventional aircraft configurations, such as Blended-Wing-Body (BWB) aircraft and B2 wing, are being investigated and researched with the aim to develop more efficient aircraft configurations, i...

ANALYSIS OF SOFT STORY MULTISTORED STEEL STRUCTURE BUILDING

This paper focusing on soft storey Multi-storey steel structure buildings, These building are becoming increasingly common and economical in developed and developing countries with the increase in urbanization all over t...

 Economic Load Distribution Among Generating Plant Using Software Based on Articial Neural Network (ANN).

 This paper presents an application system that provided the best load distribution for optimal power flow (OPF) with minimal fuel cost using artificial neural network (ANN). The idea was informed by the applicatio...

 Efficient Technique for Improving the Frequency Response of CIC Compensation

 This paper presents a new method to improve the frequency response of CIC compensation filter. After the CIC filter cascaded the fir filter which has inversed magnitude response to CIC compensation filter was prop...

Download PDF file
  • EP ID EP117056
  • DOI -
  • Views 95
  • Downloads 0

How To Cite

M. S. Aainawala 1, (30). Design of Multistoried R.C.C. Buildings with and without Shear Walls. International Journal of Engineering Sciences & Research Technology, 3(7), 498-510. https://europub.co.uk/articles/-A-117056