DESIGN ON ADμC812 SCM BASED MULTICHANNEL TEMPERATURE INTEGRATION INTELLIGENT INSTRUMENT

Journal Title: Topics in Chemical & Material Engineering (TCME) - Year 2018, Vol 1, Issue 1

Abstract

This paper introduces the design of intelligent temperature meter based on high precision data acquisition chip ADμC812. The realization methods of key technical such as linearization, scaling and digital filtering in the design of temperature sensor are described. This paper has reference value for the design of single chip integrated intelligent instrument.

Authors and Affiliations

Chu Weihua, Xie Minwei, Gu Guangwu

Keywords

Related Articles

DEFECT CHEMISTRY AND LOW-LOSS CHARACTERISTICS OF ND-DOPED BATIO3 DIELECTRIC CERAMICS

(Ba1–xNdx)Ti1–x/4O3 (x = 0.03‒0.06) (BNT) ceramics with a single-phase perovskite structure were prepared using the mixed-oxides method. The structure, microstructure, point defects, defect chemistry, and dielectric prop...

A NEW INTEGER-VALUED AUTO-REGRESSIVE MODEL BASED ON BINOMIAL THINNING OPERATOR

The integer-valued time series appears in many areas of real life, for example, medical care, economics, transportation, insurance, finance, and so on. Especially, we are in the big data period and all kinds of dispersed...

QUALITY CONTROL OF SAN’AO TABLETS VIA X-RAY DIFFRACTION AND ELECTRON SPIN RESONANCE TECHNIQUES

Both X-ray diffraction (XRD) and electron spin resonance (ESR) techniques were used to investigate San’ao tablets and their ingredients. Three XRD peaks at 2θ = 16.10°, 22.52° and 34.46°, which arise mainly from a kind o...

ROGRESS IN THE HYDRO-AMINATION OF ALCOHOLS

Aliphatic amine is an important intermediate of fine chemical industry. It is main used in pharmaceutical, foodstuff, cosmetics and fine chemicals industries. It has a variety of synthetic routes. The Progress in the hyd...

EFFECT OF MEA HOT-PRESSING ON THE PERFORMANCE OF DIRECT METHAN OL FUEL CELLS

MEA based on Nafion 115 has been prepared with GDL-based method for direct methanol fuel cell applications. The results of unit cell tests show that different temperature and pressure of hot-pressing during MEA preparati...

Download PDF file
  • EP ID EP413415
  • DOI 10.26480/icnmim.01.2018.01.04
  • Views 81
  • Downloads 0

How To Cite

Chu Weihua, Xie Minwei, Gu Guangwu (2018). DESIGN ON ADμC812 SCM BASED MULTICHANNEL TEMPERATURE INTEGRATION INTELLIGENT INSTRUMENT. Topics in Chemical & Material Engineering (TCME), 1(1), 1-4. https://europub.co.uk/articles/-A-413415