DETERMINATION OF CURRENT SETTING TIME IN INDUCTIVE LOAD OF VOLTAGE-TO-CURRENT CONVERTER UNDER NON-HARMONIC INFLUENCE
Journal Title: Вісник Національного університету "Львівська політехніка", серія "Радіоелектроніка та телекомунікації" - Year 2013, Vol 766, Issue 2013
Abstract
The paper presents analysis of problems dealing with the determination of the current setting time in the inductive component of the complex load of Voltage-to-current (VTC) converter under non-harmonic input influence. There is showed the change in the transient response and in the current setting time of the inductor on changing the VTC converter and complex load parameters. Expression to determine the current setting time of complex load of VTC converter at given level of dynamic error is presented. The estimation of dynamic error in determining the current setting time is presented in accordance with the time dependencies of transient responses of current setting in inductive load of VTC converter with complex load’s and VTС’s converters different parameters. The mathematical model of precision VTC converter [1] with deflection system (DS) of cathode-ray tube (CRT) of television scanning optical microscope connected to its output has been designed and is presented as a complete equivalent circuit taking into account the resistance and parasitic capacitance of load. In accordance with the set conditions of raster formation on screen of such CRT, the control of converter is carried out by non-harmonic signal with variable shape, frequency, amplitude and displacement [2]. Precision VTC converter built as parallel circuit with a deep DS’s current feedback, the signal of which is formed on the feedback resistor, which is connected in series with the load, has been studied. To ensure the aperiodic current setting the bypass resistor is connected to the load in parallel. While analyzing this circuit we’re considering that: the static error due to instability of comparison resistors and feedback resistor is equal to zero, the cutoff frequency of VTC converter is higher than the resonant frequency of the load, and the error due to resistance of DS is compensated. The mathematical model allows to carry out a complete theoretical study of precision VTC converter and to get expressions to determine the parameters upon certain conditions: 1) supply voltage of VTC converter is higher than the maximum voltage on the DS during the transition process; 2) amplifier is presented as one inertial circuit with real parameters: unity gain frequency fВ , gain amplifier K0 ; 3) the resistance of DS rL and parasitic capacitance CL are taken into account at analysis; 4) considered that the feedback resistor RЗЗ is non-inductive; 5) the current flowing through the resistor R2 relative to current of feedback resistor is very small and it is neglected.
Authors and Affiliations
V. Vasylyuk, Volodymyr Shkliarskyy
METHOD OF SUBSCRIBER NETWORK LOAD BALANCING IN CELULAR NETWORK
This paper is devoted to the solving the problem which occurs in cellular networks at times of peak busy hour when the radio resources are ended in one or more cells. Proposed method increases the availability of radio r...
SYNTHESIS AND PHOTODYNAMIC PROPERTIES OF COLLOIDAL SILVER SOLUTIONS
This work presents the results of research the electromagnetic radiation influence on the change in the geometric shape of spherical silver nanoparticles, obtained by method of photostimulated recovery of Ag ions from sa...
RESEARCH OF THE FREQUENCY PLANNING METHODS FOR CELL NETWORKS BASED ON LTE AND GSM TECHNOLOGIES
Modern researches in field of mobile network depend on network infrastructure in a specific region. Nowadays, the actual issue is reforming of the existing frequency range for LTE deployment. The most common band is 900/...
POWER SPECTRAL DENSITY EVALUATION BASED ON WELCH’S PERIODOGRAM FOR COGNITIVE RADIO
In this paper considered spectrum sensing methods for cognitive radio that based on energy detection. The periodogram method is a DFT based method to estimate power spectral density (PSD). The name of the periodogram com...
METHOD OF SMOOTHING INPUT LOAD ON THE ONLINE CHARGING SYSTEM
Charging users for a server operator billing involves performing a number of operations. Each service provided by the operator or service provider customers, charged at a separate scheme, as the bottleneck in the process...