DETERMINATION OF ECONOMICALLY JUSTIFIED PARAMETERS OF SYNCHRONOUS DISCONNECTION AT LOW-VOLTAGE CIRCUIT SWITCHING VIA A SYNCHRONOUS VACUUM CONTACTOR

Abstract

Dependence of a single switching procedure cost upon the contact opening delay time and delay-time spread is derived for a low-voltage synchronous vacuum contactor. For different cost levels, boundaries of permissible values of delay-time and delay-time spread are specified.

Authors and Affiliations

A. V. Verkhola

Keywords

Related Articles

THE RESONANT OVERVOLTAGE IN NON-SINUSOIDAL MODE OF MAIN ELECTRIC NETWORK

Purpose. The resonant overvoltage arises in main electrical networks as a result of random coincidence of some parameters of circuit and its mode and it may exist for a relatively long time. Therefore, the traditional me...

ANALYSIS OF ELECTROMAGNETIC PROCESS IN COMBINED INDUCTOR SYSTEMS, AS TOOLS FOR STRAIGHTENING OF MODERN CAR

The field in combined inductor systems exists only over workpiece, it occurs at only a low-frequency circular magnetic field. In this paper electromagnetic processes in tools of the magnetic pulse attraction (the combine...

DETERMINATION OF ELECTROMAGNETIC PARAMETERS AND PHASE RELATIONS IN TURBO-GENERATORS BY THE AUTOMATED CALCULATION OF THE MAGNETIC FIELD IN THE SOFTWARE ENVIRONMENT FEMM

The theoretical bases of calculation of electromagnetic quantities and time-phase relationship are presented for the turbo-generators. This is done by numerical calculations of the magnetic field in the software environm...

MODELING OF EQUIVALENT STIFFNESS OF A MAGNETIC SPRING OF VIBRATION EXCITER BASED ON COAXIAL-LINEAR MOTOR

Purpose. The research of the influence of value and direction of current on the equivalent spring magnetic force based on coaxial-linear motor (CLM – MS). Methodology. We carried out investigation of the equivalent harsh...

IMPROVING OF ELECTROMECHANICAL SERVO SYSTEMS ACCURACY

Aim. Improving of accuracy parameters and reducing of sensitivity to changes of plant parameters of nonlinear robust electromechanical servo systems of guidance and stabilization of lightly armored vehicle weapons based...

Download PDF file
  • EP ID EP302281
  • DOI 10.20998/2074-272X.2014.2.05
  • Views 80
  • Downloads 0

How To Cite

A. V. Verkhola (2014). DETERMINATION OF ECONOMICALLY JUSTIFIED PARAMETERS OF SYNCHRONOUS DISCONNECTION AT LOW-VOLTAGE CIRCUIT SWITCHING VIA A SYNCHRONOUS VACUUM CONTACTOR. Електротехніка і Електромеханіка, 0(2), 24-27. https://europub.co.uk/articles/-A-302281