Determination of Glutathione Reductase Activity Changes Exposed to Some 2-Aminothiazole Derivatives
Journal Title: Cumhuriyet Science journal - Year 2019, Vol 40, Issue 1
Abstract
In this work, effects of concentrations ranging from 0 to 500 mg/L of some 2-aminothiazole derivatives such as 4,4’-(disulfanediylbis(methylene))bis(thiazol-2-amine) dihyrochloride (DMTA) and 2-amino-4-(chloromethyl)thiazole hydrochloride (ACT) on glutathione reductase from baker's yeast (Saccharomyces cerevisiae) (GR) were investigated. With exposure of 25, 50, 100, 250 and 500 mg/L concentrations, % GR activity changes were calculated as -5.29 ; -3.85 ; -2.40 ; -6.73 and -10.58 in DMTA applications, while these changes were calculated as +0.98 ; 0.00 ; -0.49 ; -2.45 and 0.00 in ACT applications, respectively. This work indicated that there was a slight decrease in GR activity with the increase of DMTA concentrations and there was no significant change in GR activity with the increase of ACT concentrations. But according to control activities, no statitistical changes were observed in GR activities with exposure of these 2-aminothiazole derivatives (p > 0.05, n=3).
Authors and Affiliations
Hasan KARADAĞ, Emine EROĞLU, Cumhur KIRILMIŞ
On the Solution of An Ill-Posed Boundary Value Problem for Second-Order Evolution Equations
In this work, we deal with an ill-posed boundary value problem for multidimensional second-order evolution equations with variable coefficients. By using the given data, we reduce the problem to a functional equation and...
Effects of Calcined Phosphogypsum on the Geotechnical Parameters of Fine-Grained Soils
In this article, the using of waste materials has been studied such as phosphogypsum in the alteration of fine-grained soils in order to upgrade the geotechnical properties as a construction material. Standard Proctor te...
Experimental Investigation of Cooling - Heating Performance of Counter Flow Ranque-Hilsch Vortex Tubes Having Different Length Diameter Ratio
In this study, a counter flow Ranque-Hilsch Vortex Tube having 6 nozzles was experimentally investigated. The vortex tube’s Length – diameter (L/D) ratios were 10 and 12.5 and compressed air was used as working fluid and...
Archimedean Copula Estimation Parameter with Kendall Distribution Function
In the literature, up to now, it is common that for Gumbel, Clayton and Frank calculated Kendall Distribution function and to the extent those applications have been made. In this paper, we made Kendall Distribution fun...
Thickness Dependent Dielectric Loss of Plasma Poly (Ethylene Oxide) Films
Dielectric properties of plasma poly (ethylene oxide) (pPEO) thin film samples were investigated at room temperature. The thin film samples with different thicknesses were deposited by plasma assisted physical vapor depo...