DETERMINATION OF IRBESARTAN AND SINENSETIN SIMULTANEOUSLY BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY AND THEIR APPLICATION TO DRUG INTERACTION STUDY IN RAT PLASMA
Journal Title: International Journal of Pharmacy and Pharmaceutical Sciences - Year 2016, Vol 8, Issue 1
Abstract
Objective: To determine and validate of irbesartan and sinensetin simultaneously by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and application of this method to study a pharmacokinetic interaction of irbesartan and ethanol extract of Orthosiphon stamineus herba in rat plasma.Methods: The irbesartan and sinensetin were simultaneously extracted from plasma by protein precipitation with acetonitrile. Samples containing irbesartan and sinensetin were analyzed by using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with C18 column Acquity® (100 mm × 2.1 mm), 1.7 μm particle size column at 40 °C. The gradient system of mobile phase composition was a mixture of acetonitrile and 0.1% formic acid (40:60 v/v), which was pumped at a flow rate of 0.3 ml/min. Mass detection was performed on Waters Xevo Triple Quadrupole equipped with an electro spray ionization (ESI) source at positive ion mode in the multiple reaction monitoring (MRM) mode. Irbesartan was detected at m/z 429.1>205.9, sinensetin was detected at m/z 373>342.9 and losartan as an internal standard was detected at m/z 423.05>404.9.Results: The method was validated according to EMEA guidelines which showed good reproducibility and linearity of 0.99, the lower limit of quantification (LLOQ) were 25 ng/ml and 250 ng/ml for irbesartan and sinensatin, respectively. The precision (% CV) values of within-run and between-run analysis is 9.3-5.25% and 1.52–5.47% (for irbesartan), 1.52–5.09% and 2.47–9.14% (for sinensetin) whereas the accuracy (% diff) of both irbesartan and sinensetin were less than 20%. Stability studies revealed that irbesartan and sinensetin have been stable for 24 h at room temperature, 24 h in the autosampler, 3 freeze-thaw cycles, and at least 30 d at-20 oC. The validated method was applied to evaluate pharmacokinetic interactions of irbesartan and ethanol extract of Orthosiphon stamineus herba in rat plasma.Conclusion: The developed LC/MS-MS method is valid to evaluate irbesartan and sinensetin simultaneous in vitro and showed good selectivity, linearity, accuracy, precision, matrix effect, and stability. The method was successfully applied to study the pharmacokinetics interaction of irbesartan and Orthosiphon stamineus herba in rat plasma.Â
Authors and Affiliations
Nurmeilis . , Yahdiana Harahap, Fadlina Chany Saputri, Abdul Munim, Rianto Setiabudy
RP-HPLC METHOD DEVELOPMENT, VALIDATION, AND QUANTIFICATION OF LORNOXICAM IN LIPID NANOPARTICLE FORMULATIONS
Objective: A simple, reliable, sensitive and validated reversed phase-high performance liquid chromatography (RP-HPLC) method was developed for quantification of lornoxicam (LX) in rat plasma.Methods: Solid lipid nanopar...
SURVIVAL ANALYSIS FOR THE RISK OF DEVELOPING HEART ATTACK
Heart disease is the leading cause of death among Filipinos, accounting for 1 out of every 5 deaths in the past year. Each year, 170,000 Filipinos die from cardiovascular diseases, up from 85,000 more than 20 y ago. This...
VIRTUAL SCREENING AND ADMET ANALYSIS FOR IDENTIFICATION OF INHIBITORS AGAINST ACETYLCHOLINESTERASE ASSOCIATED WITH ALZHEIMER'S DISEASE
Objective: Alzheimer’s disease a progressive neurodegenerative disorder characterized by oxidative stress, amyloid β deposition and due to low level of neurotransmitter acetylcholine in the brain. the reduction of ace...
DISCRIMINANT ANALYSIS OF PURIFICATION ON TURMERIC (CURCUMA LONGA LINN) SAMPLES BASED ON PHYTO-PHARMACOGNOSTICAL AND MULTIVARIATE CHEMOMETRIC TECHNIQUE
Objective: To establish an acceptable identification system of various purification effects in context classical based different media on turmeric samples and relates its altering pattern in favor of phyto-pharmacognosti...
DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF PIPERAQUINE PHOSPHATE AND DIHYDROARTEMISININ IN BULK
High Performance Liquid Chromatography (HPLC) methods are described for determination of drugs as a single or in combination in bulk or pharmaceutical formulation. The objective of the present study was to develop and va...