Determination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore

Journal Title: International Journal of new Chemistry - Year 2019, Vol 6, Issue 3

Abstract

In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed from them. The designed electrode could also be used in partially non aqueous mediums up to the presence of 20% of organic solvents without any tangible alteration in Nernstian slope and linearity domain. The response time and life span of the proposed electrode were 20s and 2 months respectively. The function of the electrode was inspected in solutions with different pH value and also as an indicator electrode in potentiometric titration with EDTA.

Authors and Affiliations

Neda Hajizadeh

Keywords

Related Articles

Study of the Chemical Properties of RDX High-Energy Element and its Derivatives with Different Nanostructures of Mass by Functional Density Theory

In this research, RDX energy derivatives with different carbon nanoparticles under different temperature conditions were studied using density functional theory. For this purpose, the materials were first geometric optim...

Quantum Mechanic Studies of Natural Bond Orbital & Stabilities of [CuCH2SiMe3]4Complexes With Different Halogens

The asymmetric unit of the title compound, Contains two independent molecules. The Cu atoms are four coordinated in distorted tetrahedral configuration by two atoms from 5,5`-dimethyl-2,2`- bipyridine and two terminal a...

Effect of support nature on performance and kinetics of nickel nanoparticles in toluene hydrogenation

The kinetics of toluene hydrogenation over Ni-supported catalysts with various supports was investigated under the wide range of conditions as 130 to 210 °C reaction temperature, 2.6×10-5 to 5.9×10-5 atm partial pressure...

A simple method for the recovery of selenium from copper anode slime sample using alkaline roasting process

The recovery of selenium from Iranian sar-cheshmeh copper anode slime has been investigated. Copper anode slimes are containing varying precious metals, such as: gold, silver, selenium and tellurium. They are being extra...

Theoretical study of the properties of adenine amino acid tetomers with C60

In this research at the Adenine tautomers and their fullerene derivatives were optimized. NBO calculations and NMR for the tautomers and their Fullerene derivatives were carried out at the B3lyp/6-31G*quantum chemistry l...

Download PDF file
  • EP ID EP46235
  • DOI https://dx.doi.org/10.22034/ijnc.2018.33456
  • Views 265
  • Downloads 0

How To Cite

Neda Hajizadeh (2019). Determination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore. International Journal of new Chemistry, 6(3), -. https://europub.co.uk/articles/-A-46235