Abstract

It is very important to pay attention to the spatial resolution of the SPECT tool regularly every week to ensure the SPECT plane works optimally so that it can produce more accurate image quality. Using the MATLAB program can help to determine the FWHM value and spatial resolution. In the MATLAB program to calculate the value of FWHM using the ESF and PSF methods, the FWHM values obtained the value of spatial resolution. In this research, several detector distances are used to obtain the best spatial resolution values. the spatial resolution obtained is 0.01 lp/mm0.04 lp/mm with different distances. The most optimum value is obtained at a distance of 20cm from the detector with a spatial resolution value of 0.04 lp/mm. Quality Control of spatial resolution of images through FWHM calculations can be calculated using the ESF and PSF methods in the Matlab program

Authors and Affiliations

Nofrita Angelina Metungku

Keywords

Related Articles

Study on impact of patient related variables on CD4 count and opportunistic infections in HIV seropositives

Background Opportunistic infections are the hallmark manifestations of AIDS. To decrease the incidence of OI’s in PLHIV, there is a need to study the impact of all relevant factors which may be a key for the development...

RaktawahaStrotas and its Correlation with Mulasthan as a Yakrit (Liver)

“Srotas are the channels, which are widely spread all over the body, where circulation of the fluid occurs irresistibly and continuously. As per Ayurveda, Strotas are the important aspect of study like that of Tridosh an...

A study to assess neonatal outcomes followed by caesarean section at Orotta National Referral Maternity Hospital, Asmara, Eritrea

Out of the estemated130 million infants born each year worldwide, 4 million die in the first 28 days of life.3/4 of neonatal deaths occur in the first week and more than ¼ occur in the first 24 hours. Neonatal deaths acc...

Isolation and characterisation of cryptolepine from SidaacutaBurm and its antimycobacterial activity

Background Sida acutais a shrub indigenous to pantropical areas, widely distributed in regions and found in pastures, waste lands, cultivated lands, roadsides, lawns and planted forests. Sidaacuta is ethanomedically used...

A case presentation on acute ischemic stroke

Background information A 52 years old male patient has been admitted in the hospital with the chief complaints of slurred speech, weakness in right extremities and he does have a medical history of hypertension, diabetes...

Download PDF file
  • EP ID EP535940
  • DOI -
  • Views 61
  • Downloads 0

How To Cite

Nofrita Angelina Metungku (2019). Determination of spatial resolution using TC99M on Spect with distance detector variations. International Journal of Allied Medical Sciences and Clinical Research, 7(1), 96-99. https://europub.co.uk/articles/-A-535940