Determination of structural behavior of a unreinforced masonry Clock Tower using FEM analysis
Journal Title: American journal of Engineering Research - Year 2016, Vol 5, Issue 1
Abstract
In this paper it is presented the structural assessment of the Clock Tower found in the castle of Preza, an old historical landmark built during the beginning of 15th century. The structural behavior is analyzed using FEM modeling in order to examine at what extent the structural defects endanger the stability of the tower also considering the geotechnical properties of the soil under the basement of the tower. The geometrical data are acquired by means of terrestrial laser scanner (TLS). Mechanical properties of the constituents were defined through experimental tests on stone samples extracted from the tower. As a result, a better overview of the structural conditions is established and improvement techniques are suggested in order to enhance the performance under both static and dynamic loads.
Authors and Affiliations
Enea Mustafaraj1 ,, Yavuz Yardım1,2
Applications Of Differential Transform Method To Integral Equations
In this article, the Differential Transform Method is applied for solving integral equations. The approximate solution of the integral equation is calculated in the form of series with easily computable components. This...
A Case Study on the Design and Feasibility of One Man Copter
Air transportation has been a topic of intense research and development from the past five decades owing to wide applicability. Appreciable work has been accounted from fulfilling basic needs to incorporation of special...
Energy Consumption Assessment of Mobile Cellular Networks
The increase in energy consumption of mobile cellular networks has now become a concern not only because of increase in the cost of energy on the part of mobile network operators but also because of its adverse effect on...
Fault Detection and Isolation (FDI): Efficient Technique and Analysis
This paper deals extensively on Fault Detection and Isolation (FDI) techniques, using a three tank system with two inputs, three measured outputs and three States. And describes how the Fault detection and Isolation was...
Influencers Of Residents’ Adaptive Actions In Response To Indoor Thermal Discomfort In A Warm-Humid City
The paper presents an evaluation of residents’ adaptive actions influencers in response to thermal discomfort within selected neighborhoods of Ibadan, a warm-humid Nigerian city. It was found that 63.6% of respondents we...