Determination of suspended erythrocyte volume range and establishment of its internal control standard

Journal Title: Chinese Journal of Blood Transfusion - Year 2023, Vol 36, Issue 3

Abstract

Objective To determine the volume range of suspended erythrocyte and establish its internal control standard. Methods The theoretical value of suspended erythrocyte volume was calculated according to the screening criteria of healthy blood donors and Quality Requirements for Whole Blood and Blood Components. A total of 2 410 bags of 1 U and 2 U suspended erythrocyte were randomly selected and weighed, and the volume range were formulated by ±2S and ±10% respectively and then compared to determine the volume range in line with the actual situation of our center. Results The theoretical volume range of 1 U and 2 U suspended erythrocyte were 117-160 mL vs 234-320 mL, and the actual volume range were 142-180 mL vs 276-393 mL. The volume range of 1 U and 2 U suspended erythrocyte formulated by ±2S were 145-181 mL vs 298-358 mL, and by ±10% were 147-179 mL vs 295-361 mL. The hematocrit and hemoglobin content of suspended erythrocyte within the actual volume range met the quality requirements. There were fluctuations in the volume of suspended erythrocyte from different regions. Conclusion Based on the actual situation of our center and the sampling results of suspended erythrocytes in recent two years, 163 mL±10% and 328 mL±10% were determined as the internal control standards of 1 U and 2 U suspended erythrocyte, respectively. Blood centers should establish accurate and feasible standard of suspended erythrocyte according to the actual situation.

Authors and Affiliations

Jing LAN, Hua XU, Xin CAO, Jiawei LI, Jin DING, Peng PENG, Na LIU, Na FENG

Keywords

Related Articles

Establishment and evaluation of a fluorescent antibody assay against varicella-zoster virus membrane antigen based on Vero E6 cells

Objective To establish and evaluate a fluorescent antibody to membrane antigen (FAMA) method for detecting antibodies against varicella-zoster virus (VZV) based on Vero E6 cells. Methods Based on the adapted VZV-Oka-E6 s...

Expert consensus on screening for unexpected red blood cell antibodies

Unexpected red blood cell antibodies refer to antibodies except for anti-A and anti-B in normal ABO blood group, and are widely present in patients with pregnancy, transfusion, transplantation, injection of immunogenic s...

A content analysis of the provincial laws and regulations for voluntary blood donation

Objective To perform quantitative analysis on the sample provincial laws and regulations for voluntary blood donation, and provide reference for further revision of laws and regulations. Methods 31 study samples were cur...

Cases report and diagnosis and treatment of passenger lymphocyte syndrome after liver and renal transplantation

Objective To summarize the clinical features, serological features, blood transfusion protocols and treatment of 3 cases of passenger lymphocyte syndrome(PLS) after ABO-incompatibility liver and renal transplantation in...

Efficacy and safety evaluation of plasma-derived human coagulation factor Ⅷ in patients with hemophilia A

Objective To evaluate the efficacy and safety of plasma-derived human coagulation factor Ⅷ (FⅧ) in the treatment of patients with hemophilia A. Methods A multi-center and open, SAT(single-arm trials) clinical study was c...

Download PDF file
  • EP ID EP738517
  • DOI 10.13303/j.cjbt.issn.1004-549x.2023.03.018
  • Views 5
  • Downloads 0

How To Cite

Jing LAN, Hua XU, Xin CAO, Jiawei LI, Jin DING, Peng PENG, Na LIU, Na FENG (2023). Determination of suspended erythrocyte volume range and establishment of its internal control standard. Chinese Journal of Blood Transfusion, 36(3), -. https://europub.co.uk/articles/-A-738517