Determination of titanium in orthodontic with modified graphene paste electrode and ionic liquid by potentiometric method

Journal Title: Journal of Research in Medical and Dental Science - Year 2017, Vol 5, Issue 3

Abstract

Two new potentiometric methods for determination of titanium in pure form and in its pharmaceutical form are developed. In the first method, new modified carbon paste electrode based on(SAPD) as a chemical modifier. The construction of carbon paste electrodetitanium ion-selective electrode and its use in the potentiometric determination of titanium in pharmaceutical preparations and orthodontic cages is described. The electrode displays a linear log [Ti3+] versus EMF response over a wide concentration range of 4.1×10−7 to 1.2×10−3 with nernstian slope of 19.1±0.1 mV/decade with limit of detection 1.1×10−7 over the pH range 3.8–7.8; a response time of <10 s; and use for at least 3 months without any significant potential divergence the presence of the complex Ti(OH)2+ ion explains the slope of the response curve. The proposed sensor shows reasonable discrimination ability. The modified electrode was applied as indicator electrode to determine Ti(III) in aqueous samples with satisfactory results.

Authors and Affiliations

Sara Sahebnasagh, Mahmoud Ebrahimi, Mohammad Reza Bozorgmehr

Keywords

Related Articles

Histologic and Histomorphometric Evaluation of Maxillary Sinus Floor Elevation Using Nanobone® and Easy-Grafttm Crystal: A Split-Mouth Clinical Trial

Maxillary sinus floor elevation is an effective method for bone augmentation in the posterior maxilla. Due to the limitations of autogenous bone grafts, bone substitutes are often used for this purpose. This study sought...

The risk factors for infected and perforated appendicitis

It is believed that the appendix will be perforated if the surgery of an acute appendicitis is delayed. However, some of the recent studies, contested this hypothesis and shown that only a delay in the treatment cannot f...

Investigating the Sizes of Anatomical Landmarks of Coronal Pulp in the First Permanent Human Molars on Bite Wing Radiography

Knowledge of dental pulp anatomy is effective in preventing random pulp exposure in remedial procedures. This study determined and compared the dimensions of the pulp chamber and the contours of the tooth to the pulp cha...

Impact of Neck Dissection in the Treatment of Oral Squamous Cell Carcinoma

The clinical outcome of the overall recurrence after SND and RND in the treatment of oral squamous cell carcinoma; relate the recurrence rate of pathological staging and the significance of PORT in reducing recurrence. F...

Barriers and facilitators of evidence-based practice from the perspective of nurses who working in northwestern psychiatric centers of Iran

Evidence-based practice is an indicator of the quality of health and treatment care and plays an important role in improving the quality of nursing care. The purpose of the study was to determine the barriers and facilit...

Download PDF file
  • EP ID EP344712
  • DOI -
  • Views 127
  • Downloads 0

How To Cite

Sara Sahebnasagh, Mahmoud Ebrahimi, Mohammad Reza Bozorgmehr (2017). Determination of titanium in orthodontic with modified graphene paste electrode and ionic liquid by potentiometric method. Journal of Research in Medical and Dental Science, 5(3), 88-92. https://europub.co.uk/articles/-A-344712