Determining high quasi­hydrostatic pressure up to 7 GPa at a temperature to 1,400 °С using resistive sensors

Abstract

<p>A differential method for measuring high quasi‒hydrostatic pressures for six‒punch pressing installations has been constructed by building a load‒carrying characteristic р=f(Q), where p is the value for pressure in a quasi‒hydrostatic cell of high‒pressure, Q is the force of the press. Pressure in the cell is measured by using the measurement of a temperature difference between the polymorphic transformations into Co(α→β) and Fe(α→γ), melting of Cu and Ag; the measurements are performed by resistometry. The initial data used were the lines of polymorphic transitions in iron (BCC‒FCC) and cobalt (FCC‒HCP) within the ranges p=4‒7 GPa and T=500‒700 °C, examined in detail earlier in the p, T‒diagrams, as well as copper and silver melting curves at p=4‒7 and T=1,150‒1,400 °C.</p><p>The database of initial data is represented in the analytical form, which has made it possible to use them to determine pressure in the cell at high temperatures based on the values for magnitudes of the differential temperature difference ΔT<sub>d</sub>, which was measured experimentally for the Co<sup>α‒β</sup>–Fe<sup>α‒γ</sup> and Ag<sup>L.</sup>–Cu<sup>L. </sup>sensors, designed in the current paper; we have described the features in assembling differential sensors and their electrical connections in order to perform the process of measuring the magnitudes for ΔT<sub>d</sub>. We have designed structures for the high-pressure cells to conduct experiments on measuring ΔT<sub>d</sub> using thermocouples and a circuit that registers a change in the resistance of sensors at phase transformations.</p><p>The procedure applied has made it possible to determine pressure in the quasi-hydrostatic cells of six-punch setups by building load characteristics. The main benefits of the devised method for measuring quasi‒hydrostatic pressures by resistometry are its relative simplicity and a significant increase in the accuracy of pressure determination. The latter is achieved through the mutual elimination of corrections of pressure impact and parasitic components for the magnitude of thermo‒EMF of thermocouples in determining the values for a temperature of phase transformations in the resistive sensors Co‒Fe and Ag‒Cu.</p><p>The data obtained could be used for monitoring and measuring pressures in the cells of six-punch pressing installations with a plunger diameter of 560‒950 mm.</p>

Authors and Affiliations

Sergey Ivakhnenko, Valentyn Lysakovskyi, Oleksandr Savitskyi, Andrii Burchenia

Keywords

Related Articles

Development of a decontamination system for decomposing N-(phosphonomethyl)glycine

<p>The study has specified the influence of activators on the decomposition of N-(phosphonomethyl)glycine under the effect of hydrogen peroxide and potassium hydroxide. As decontamination systems, potassium hydroxide, hy...

Definition of a composite index of glazing rooms

<p>The effect of geometrical parameters of rooms and window openings on the value of the daylight factor (DF) in the reference point on the work surface is considered in the article. This is important, as while using a l...

Identification of properties of recycled high­density polyethylene composites when filled with waste mud solids

<p>The possibility of increasing recycling volumes of drilling waste using as a filler for producing polymer composites is considered. As a result of the research, modification of recycled high-density polyethylene with...

Research into the impact of structural features of combustion chamber in energy-technological units on their operational efficiency

<p>The experimental studies of the influence of the degree of masonry development (geometry) and aerodynamics of the combustion chambers (circuits of combustion products removal) on the energy-technological indicators of...

Examining the efficiency of electrochemical purification of storm wastewater at machine­building enterprises

<p class="a">We have examined the composition of polluted storm water discharged from the territory of a machine­building enterprise. It was established that the territory was unevenly polluted, with the surface wastewat...

Download PDF file
  • EP ID EP666406
  • DOI 10.15587/1729-4061.2019.168712
  • Views 45
  • Downloads 0

How To Cite

Sergey Ivakhnenko, Valentyn Lysakovskyi, Oleksandr Savitskyi, Andrii Burchenia (2019). Determining high quasi­hydrostatic pressure up to 7 GPa at a temperature to 1,400 °С using resistive sensors. Восточно-Европейский журнал передовых технологий, 3(5), 13-20. https://europub.co.uk/articles/-A-666406