Development of 2.2 kJ Plasma Focus Device and its Operation in various gases

Journal Title: Scholars Journal of Engineering and Technology - Year 2014, Vol 2, Issue 3

Abstract

A design of 2.2 kJ plasma focus (PF) device has been constructed using a set of four capacitors which are connected in parallel and has capacity of (30.84μf) and charged with voltage (12kV). This device was operated in various gases; Helium, Argon and Nitrogen in the range of pressure from 0.2 to 3.6 torr. Exchanging the Teflon flat insulator with the Pyrex glass tubular insulator between the two coaxial electrodes surrounding the inner electrode IE with a thickness 3mm and 3cm in length (effective length 25 mm from the surface of outer electrode (OE) back plate) for beam dense. Another modification was made to the discharge circuit connections to minimize the inductance of the circuit across the length of the coaxial cables has length of 2 meter and a number 0f 20 cables which are connected in parallel compared to the previous set up of the device. The optimum operating pressures have been established for each gas type under consideration in this work. We get a good focusing from this device with best spike voltage of 4.5 kV for nitrogen gas at the time of the first peak of current (TImax) with pressure of 0.35 torr, 2 kV for argon at time (TImax) with pressure of 0.3 torr and 1kV for helium at time (TImax) with pressure ranged between (o.3 torr). The discharge current has a maximum value of 180 kA at pressure of 1.2 torr, 170 kA at pressure of 0.5 torr and 120 kA at pressure of 0.2 torr for helium, argon and nitrogen gas respectively. Keywords: Plasma/Focus/Voltage spike/Focusing time/Max. current time

Authors and Affiliations

G. M. El-kashef

Keywords

Related Articles

Effect of Different Storage Methods on the Proximate Composition and Functional Properties of Cream-Skinned Sweet Potato(Ipomea batatas Lam)

In this study, the effect of different storage methods on the proximate composition and functional properties of sweet potato (Ipomoea batatas Lam.) was investigated. The sweet potato tubers were harvested from a local f...

A Case Study: A Process FMEA Tool to Enhance Quality and Efficiency of Bearing Manufacturing Industry

This Paper is an attempted to represent the potential tool for evaluates the problem of manufacturing process by implementing the process FMEA. This study has a goal to concentrate and eliminate the potential problem for...

Design and Implementation of A Knowledge-Based Typhoid Fever Diagnosis Expert Advisor Using Forward Chaining Inference Mechanism

Abstract:The medical field is experiencing setbacks, medical cases almost always seems to outnumber the number of medical experts required to attend to them. This in part is due to lack of qualified doctors to handle spe...

Online Framework based on Serious Games for Healthcare:Case Studies

Abstract: Integrating serious games for Health has been proposed through a unified framework expanding current Health informatics. Healthcare from this perspective includes care for persons with physical, mental or devel...

Chemiluminescence reaction of aldehyde with hydrogen peroxide

Chemiluminescence of aldehydes (like formaldehyde, acetaldehyde, propioaldehyde and benzaldehyde) and hydrohen peroxide in presence and absence of luminol has been studied. Magnesium hydroxide was chosen for solution mak...

Download PDF file
  • EP ID EP384393
  • DOI -
  • Views 94
  • Downloads 0

How To Cite

G. M. El-kashef (2014). Development of 2.2 kJ Plasma Focus Device and its Operation in various gases. Scholars Journal of Engineering and Technology, 2(3), 360-366. https://europub.co.uk/articles/-A-384393