Development of a Wavelet-ANFIS based fault location system for underground power cables

Abstract

In the past decade, electricity demand has increased rapidly in metropolitan areas. All over the world, large scale underground power cable installations networks are replacing overhead transmission lines due to environmental concerns in densely populated areas. Underground cable systems are manufactured to have long life with reliability. However, the useful life span of these cables is not infinite. The increase in failure rates and system breakdowns on older underground power cables are now adversely impacting system reliability and many losses involved; therefore it is readily apparent that necessary action has to be taken to manage the consequences of this trend. In this paper, a method that combines wavelets and Neuro-fuzzy technique for fault location and identification is proposed. A 10km, 34.5KV, 50Hz power transmission line model was developed and different faults and locations simulated, and then certain selected features of the wavelet transformed signals were extracted to develop an ANFIS for fault location. Comparison of the ANFIS output values and the actual values show that the percentage error was established to be less than 1%. Thus, it can be concluded that the wavelet-ANFIS technique is accurate enough to be used in identifying and locating underground power line faults.

Authors and Affiliations

H. S. Zawaira, G. N. Nyakoe, C. M. Muriithi

Keywords

Related Articles

Potential of Aek Rambe river as mini hydro power plant in North Sumatera, Indonesia

The water energy is a clean energy and one part of renewable energy. An electrical power plant produces a cheap electric, no pollution and no damage during electric operation and also the water can be used back for the o...

Comparison of major peanut allergens Ara h 1, Ara h 2 and Ara h 3 between peanut cultivars from Côte d’Ivoire and the USA using SDS PAGE and Western Blots

Peanut is commonly consumed in many forms. The ubiquitous presence of peanut in processed food is responsible for an increasing number of allergic reactions due to accidental ingestion. The prevalence of peanut allergy s...

A Highly Efficient Real-Time Tracking Method in Augmented Reality System

A highly efficient real-time tracking algorithm is very important for augmented reality implementation by computer vision mode. The mean-shift (MS) algorithm is widely used in object tracking for augmented reality system...

Voltage Sag and Swell compensation using DVR to enhance Power Quality

The quick developments in power electronic technology have made it possible to mitigate voltage disturbances in power grid. Among the voltage disturbances challenging the trade, the voltage sags are considered to be the...

Active and Reactive Power Control for Grid-Connected PV Systems Using Cascaded Multilevel Converters

Photovoltaic (PV) panels generator module is the widely used system solar generated powers are cascaded and connected to the grid with a constant AC supply .pv cell which gets subjected to various intensities of sun ligh...

Download PDF file
  • EP ID EP389023
  • DOI 10.9790/1676-1201024550.
  • Views 119
  • Downloads 0

How To Cite

H. S. Zawaira, G. N. Nyakoe, C. M. Muriithi (2017). Development of a Wavelet-ANFIS based fault location system for underground power cables. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(1), 45-50. https://europub.co.uk/articles/-A-389023