Development of portable dc voltage calibrators with additive offsets adjusting

Abstract

<p>Improvement of portable equipment for controlling the DC voltage measuring channels of cyber-physical systems at the operating sites is proposed. Additive offsets and drifts make a dominant contribution to the error of portable DC voltage calibrators. Automatic correction based on the method of double switching inversion provides the opportunity to increase the productivity of multichannel system voltage meters at the operating sites. It is shown that the additive offsets during the DC voltage reproduction, in addition to the equivalent offset voltages of the operational amplifiers, ADCs or DACs, are caused by common type noises and leakage currents through the isolation of the power supply units.</p><p>In the developed structure of the DC voltage calibrator, it is proposed to use the method of double switching inversion with subsequent analog averaging of the output signal for the automatic correction of the additive offsets. The error analysis and simulation showed the principal possibility of the calibrator additive offsets correction to the values limited by the non-identity of parameters of the closed pairs of switches.</p><p>The analysis of the results of experimental studies of the voltage calibrator layout showed the invariance of the reproduced voltages from the voltage value and the location of the simulator of the additive error component in the layout structure.</p><p>The uncorrected error value in the manual mode did not exceed ±1 μV for all reproduced values of the output voltage of the layout. It has been experimentally shown that the minimum value of the uncorrected error lies at a switching frequency of about 1.2 kHz within ±5 μV. The developed scheme can be implemented in the basis of programmable systems on the chip, which significantly improves the metrological characteristics, reduces the cost and unifies portable voltage calibrators and DC resistance simulators.</p>

Authors and Affiliations

Roman Matviiv, Yurii Yatsuk, Vasyl Yatsuk

Keywords

Related Articles

Study of the oxidation kinetics of nitrite ions by potassium ferrate(VI)

<p>The oxidation kinetics of nitrite to nitrate ions by potassium ferrate(VI) in a wide range of pH, from neutral to alkaline medium has been studied. Two series of kinetic experiments based on the different technologies...

Research into cavitation processes in the trapped volume of the gear pump

<p class="1CxSpFirst">We investigated processes in the trapped volume of the gear pump, formed due to the peculiarities in the geometry of the involute gearing characteristic of the pumps of a given type. In the fluid co...

Enrichment on Bangka tin slag’s tantalum and niobium oxide contents through non-fluoride process

<p>This research explored how non-fluoride solutions including 8M NaOH, 0.8, 1.6 and 2.4 M H<sub>2</sub>SO<sub>4</sub>, and 0.1, 0.4 and 0.8 M HClO<sub>4 </sub>increased the contents of tantalum and niobium oxide through...

“The popcorn effect”: obtaining of the highly active ultrafine nickel hydroxide by microwave treatment of wet precipitate

Nickel hydroxide is widely used as an active material of supercapacitors. The most active are samples of Ni(OH)<sub>2</sub> with (α+β) layered structure synthesized in a slit diaphragm electrolyzer. However, the processe...

A study of electrochromiс Ni(OH)2 films obtained in the presence of small amounts of aluminum

<p class="1">The research is related to the synthesis of electrochromic films of nickel hydroxide with aluminum as a dopant. Films were deposited via cathodic template synthesis in the presence of polyvinyl alcohol from...

Download PDF file
  • EP ID EP528212
  • DOI 10.15587/1729-4061.2018.141515
  • Views 72
  • Downloads 0

How To Cite

Roman Matviiv, Yurii Yatsuk, Vasyl Yatsuk (2018). Development of portable dc voltage calibrators with additive offsets adjusting. Восточно-Европейский журнал передовых технологий, 5(9), 35-42. https://europub.co.uk/articles/-A-528212