Development of portable dc voltage calibrators with additive offsets adjusting
Journal Title: Восточно-Европейский журнал передовых технологий - Year 2018, Vol 5, Issue 9
Abstract
<p>Improvement of portable equipment for controlling the DC voltage measuring channels of cyber-physical systems at the operating sites is proposed. Additive offsets and drifts make a dominant contribution to the error of portable DC voltage calibrators. Automatic correction based on the method of double switching inversion provides the opportunity to increase the productivity of multichannel system voltage meters at the operating sites. It is shown that the additive offsets during the DC voltage reproduction, in addition to the equivalent offset voltages of the operational amplifiers, ADCs or DACs, are caused by common type noises and leakage currents through the isolation of the power supply units.</p><p>In the developed structure of the DC voltage calibrator, it is proposed to use the method of double switching inversion with subsequent analog averaging of the output signal for the automatic correction of the additive offsets. The error analysis and simulation showed the principal possibility of the calibrator additive offsets correction to the values limited by the non-identity of parameters of the closed pairs of switches.</p><p>The analysis of the results of experimental studies of the voltage calibrator layout showed the invariance of the reproduced voltages from the voltage value and the location of the simulator of the additive error component in the layout structure.</p><p>The uncorrected error value in the manual mode did not exceed ±1 μV for all reproduced values of the output voltage of the layout. It has been experimentally shown that the minimum value of the uncorrected error lies at a switching frequency of about 1.2 kHz within ±5 μV. The developed scheme can be implemented in the basis of programmable systems on the chip, which significantly improves the metrological characteristics, reduces the cost and unifies portable voltage calibrators and DC resistance simulators.</p>
Authors and Affiliations
Roman Matviiv, Yurii Yatsuk, Vasyl Yatsuk
Comparison of products of whey proteins concentrate proteolysis, obtained by different proteolytic preparations
<p>An important source of bioactive peptides is hydrolyzed products based on milk whey: hypoallergenic products, hydrolyzates for baby food, and products for athletes. However, in their production, proteolytic preparatio...
Experimental study into the influence of straw content in fuel on parameters of generator gas
<p>A gasifier of specific design was proposed for gasification of straw containing fuels. Combustion and regeneration zones of this gasifier have the same diameter. A mixture of wood and straw pellets was used as a fuel....
Modeling the process of polymers processing in twinscrew extruders
<p>We developed a mathematical model of the process of polymer processing in co- and counter-rotating twin-screw extruders. The model takes into account a heat transfer of a polymer with screws and a barrel, as well as r...
Development of a procedure for determining the basic parameter of aquatic ecosystems functioning ‒ environmental capacity
<p>Environmental capacity as the main parameter of functioning of aquatic ecosystems was studied. This parameter is an effective indicator of violation of structural and functional processes in the technogenically altere...
Development of the system to control milk acidity in the milk pipeline of a milking robot
<p>Acidity characterizes the suitability of milk for primary processing and is one of the key parameters monitored when accepting it at a dairy plant. Therefore, it is important to timely separate milk with lowered acidi...