Diagnostic accuracy of magnetic resonance elastography in liver transplant recipients: A pooled analysis

Journal Title: Annals of Hepatology - Year 2016, Vol 15, Issue 3

Abstract

Background and aims. We conducted an individual participant data (IPD) pooled analysis on the diagnostic accuracy of magnetic resonance elastography (MRE) to detect fibrosis stage in liver transplant recipients. Material and methods. Through a systematic literature search, we identified studies on diagnostic performance of MRE for staging liver fibrosis, using liver biopsy as gold standard. We contacted study authors for published and unpublished IPD on age, sex, body mass index, liver stiffness, fibrosis stage, degree of inflammation and interval between MRE and biopsy; from these we limited analysis to patients who had undergone liver transplantation. Through pooled analysis using nonparametric two-stage receiver-operating curve (ROC) regression models, we calculated the cluster-adjusted AUROC, sensitivity and specificity of MRE for any (≥ stage 1), significant (≥ stage 2) and advanced fibrosis(≥ stage 3) and cirrhosis (stage 4). Results. We included 6 cohorts (4 published and 2 unpublished series) reporting on 141 liver transplant recipients (mean age, 57 years; 75.2% male; mean BMI, 27.1 kg/m2). Fibrosis stage distribution stage 0, 1, 2, 3, or 4, was 37.6%, 23.4%, 24.8%, 12% and 2.2%, respectively. Mean AUROC values (and 95% confidence intervals) for diagnosis of any (≥ stage 1), significant (≥ stage 2), or advanced fibrosis (≥ stage 3) and cirrhosis were 0.73 (0.66-0.81), 0.69 (0.62-0.74), 0.83 (0.61-0.88) and 0.96 (0.93-0.98), respectively. Similar diagnostic performance was observed in stratified analysis based on sex, obesity and inflammation grade. Conclusions. In conclusion, MRE has high diagnostic accuracy for detection of advanced fibrosis and cirrhosis in liver transplant recipients, independent of BMI and degree of inflammation.

Authors and Affiliations

Siddharth Singh, Sudhakar Venkatesh, Andrew Keaveny, Sharon Adam, Frank Miller, Patrick Asbach, Edmund Godfrey, Alvin Silva, Zhen Wang, Mohammad Murad, Sumeet Asrani, David Lomas, Richard Ehman

Keywords

Related Articles

Prediction of poor graft function by means of gastric tonometry in patients undergoing liver transplantation

Introduction. Splanchnic hypoperfusion appears to play a key role in the failure of functional recovery of the graft after orthotopic liver transplantation (LT). The aim of this study was to determine if alterations of t...

Common SPINK-1 mutations do not predispose to the development of non-alcoholic fatty liver disease

Background: Non-alcoholic fatty liver disease (NAFLD) is common in obese and diabetics. Serine protease inhibitor Kazal-1 (SPINK-1) protein is highly expressed in the liver and adipose tissue of diabetic and obese sugges...

Treatment of recurrent hepatitis C post-liver transplantation

Recurrent hepatitis C after liver transplantation is universal. Graft reinfection occurs rapidly, with chronic hepatitis and rapid evolution from end-stage liver disease. Within 5 years until 30% of patients with recurre...

Clinical Analysis of Polyethylene Glycol Interferon-α Treatment in 155 Hepatitis B e Antigen (HBeAg)-Positive Chronic Hepatitis B (CHB) Patients

Purpose. This study aims to investigate the antiviral effect of polyethylene glycol (PEG)-interferon α-2a and PEG-interferon α-2b treatment on hepatitis B e antigen (HBeAg)-positive chronic hepatitis B (CHB) at the 48th...

Download PDF file
  • EP ID EP78577
  • DOI 10.5604/16652681.1198808
  • Views 101
  • Downloads 0

How To Cite

Siddharth Singh, Sudhakar Venkatesh, Andrew Keaveny, Sharon Adam, Frank Miller, Patrick Asbach, Edmund Godfrey, Alvin Silva, Zhen Wang, Mohammad Murad, Sumeet Asrani, David Lomas, Richard Ehman (2016). Diagnostic accuracy of magnetic resonance elastography in liver transplant recipients: A pooled analysis. Annals of Hepatology, 15(3), 363-376. https://europub.co.uk/articles/-A-78577