Diagnostic accuracy of pleural fluid adenosine deaminase in tubercular pleural effusion

Journal Title: International Journal of Medical Research and Review - Year 2016, Vol 4, Issue 8

Abstract

Background: In India, tuberculosis is an endemic disease. Delay in diagnosis results in poor prognosis and fast spread of the disease. The objective of the present study is to look for an effective and acceptable diagnostic test, which may be helpful to initiate early treatment to improve prognosis and reduce spread. The presence of ADA in pleural fluids reflects the cellular immune response in the pleural cavity and in particularly, the activation of T lymphocytes. Objective of study include evaluating efficacy of combined use of ADA activity diagnosing tuberculous pleural effusion. Methods: Biochemistry, cytology, and microbiology studies were performed on 164 consecutive pleural fluids. ADA were determined on all exudative effusions. Results: Pleural fluid ADA activity at a level of ≥40 U/L, the sensitivity=95.5%, specificity=93.4%, positive prediction value=94.4%, negative prediction value=94.7% and efficacy= 94.5 %. It was statistically significant (p value<0.001). Conclusion: ADA is a highly sensitive diagnostic marker of tubercular pleural effusion.

Authors and Affiliations

Aniruddha Udupa K, S. Vinod Kumar, Manju R, H. Nandeesha

Keywords

Related Articles

Adenocarcinoma in situ presenting as extensive crazy paving pattern: HRCT findings and review of literature

The crazy-paving pattern seen on HRCT is comprised of diffuse areas of ground glass attenuation. This imaging finding has numerous differentials including idiopathic, infectious, neoplastic and other miscellaneous entiti...

Epidemiology of oral poisoning in paediatrics age group

Introduction: Poisoning in children is a common and preventable cause of morbidity and mortality. Our environment is still not child-safe and the medications are not dispensed in a child-safe manner. The incidence of chi...

Rare case of gastric perforation with malrotation and volvulus: A case report

Gastric perforation in neonate has always been a catastrophe associated with high morbidity. The high mortality rate reflects to a certain extent the precariousness of the neonatal period, but the process evolves so rap...

A comparative study of clinical profile & investigative parameters of systemic lupus erythematosus patients with & without metabolic syndrome

Introduction: The Metabolic Syndrome (MetS) often contributes to increased cardiovascular risk in patients with systemic lupus erythematosus (SLE) especially in younger age group. Determining the contribution of SLE phen...

Skill based training of accredited social health activists: training effectiveness assessment using training and programme evaluation model

Background: Accredited Social Health Activists (ASHAs) are gross root health workers introduced under NRHM; for delivery of health services in rural areas. Training them for capacity building and functioning was a big ch...

Download PDF file
  • EP ID EP231004
  • DOI 10.17511
  • Views 103
  • Downloads 0

How To Cite

Aniruddha Udupa K, S. Vinod Kumar, Manju R, H. Nandeesha (2016). Diagnostic accuracy of pleural fluid adenosine deaminase in tubercular pleural effusion. International Journal of Medical Research and Review, 4(8), 1292-1297. https://europub.co.uk/articles/-A-231004