Diagnostic Accuracy of Ultrasound in Detection of Traumatic Lens Dislocation

Journal Title: Archives of Academic Emergency Medicine - Year 2014, Vol 2, Issue 3

Abstract

Introduction: Traumatic eye injuries (TEI) involved about 3% of cases referred to the emergency departments of developing countries. Lens dislocation is one of the critical cases of ophthalmic emergencies. The present study was aimed to evaluate the diagnostic accuracy of ultrasonography in detection of traumatic lens dislocation. Methods: In this cross-sectional study the findings of ultrasonography and orbital computed tomography (OCT) of head and face trauma patients, referred to Imam Reza hospital, Tabriz, Iran, from July 2013 to June 2014, have been compared. The sensitivity, specificity, positive and negative likelihood ratio, positive and negative predictive value, and accuracy of ultrasonography were calculated. Cohen's kappa coefficient was presented to assess the agreement of ultrasonography with OCT findings. Results: One hundred thirty patients with the mean age of 35.4±18.0 were evaluated (75.4% male). Sensitivity and specificity of ultrasonography were 84.6% (95% Cl: 53.7-97.3) and 98.3% (95% Cl: 93.3- 99.7), respectively. In addition, positive and negative likelihood ratio were calculated 49.5 (95% Cl: 12.3-199.4) and 0.15 (95% Cl: 0.04- 0.56), respectively. Cohen's kappa coefficient of 0.83 (95% Cl: 0.66-1.0; p<0.0001) was representative of excellent agreement of these two tests. Conclusion: The finding of this project was representative of 84.6% sensitivity, 98.3% specificity, and 96.9% accuracy of ultrasonography in detection of traumatic lens dislocation. It seems that in cases, which OCT is not possible, ultrasonography, could be an acceptable option to assess traumatic eye injuries.

Authors and Affiliations

Keywords

Related Articles

A 41-Year-Old Woman with Seizure

The patient was a 41 year old woman that was brought to the emergency department (ED) by her husband following seizure. According to the relatives accompanying her, the seizure was of tonic-clonic type, had occurred one...

Worsened Dysrhythmia after Chemical Cardioversion with Digoxin; a Case of Malpractice

The patient was a 23-year-old man referred to the emergency department (ED) with the chief complaint of palpitation. The patient experienced dizziness, cold sweating, and lightheadedness after getting up which started sp...

Validation of CRASH Model in Prediction of 14-day Mortality and 6-month Unfavorable Outcome of Head Trauma Patients

Introduction: To date, many prognostic models have been proposed to predict the outcome of patients with traumatic brain injuries. External validation of these models in different populations is of great importance for t...

The Pattern of Pre-hospital Medical Service Delivery in Iran; a Cross Sectional Study

Introduction: Pre-hospital emergency systems provide service by Franco-German and Anglo American models. This study was carried out to compare the Iranian emergency medical service (EMS) with the two models regarding tim...

Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study

Introduction: Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availabilit...

Download PDF file
  • EP ID EP321078
  • DOI -
  • Views 211
  • Downloads 0

How To Cite

(2014). Diagnostic Accuracy of Ultrasound in Detection of Traumatic Lens Dislocation. Archives of Academic Emergency Medicine, 2(3), 121-124. https://europub.co.uk/articles/-A-321078