Diagnostic Accuracy of Ultrasound in Detection of Traumatic Lens Dislocation

Journal Title: Archives of Academic Emergency Medicine - Year 2014, Vol 2, Issue 3

Abstract

Introduction: Traumatic eye injuries (TEI) involved about 3% of cases referred to the emergency departments of developing countries. Lens dislocation is one of the critical cases of ophthalmic emergencies. The present study was aimed to evaluate the diagnostic accuracy of ultrasonography in detection of traumatic lens dislocation. Methods: In this cross-sectional study the findings of ultrasonography and orbital computed tomography (OCT) of head and face trauma patients, referred to Imam Reza hospital, Tabriz, Iran, from July 2013 to June 2014, have been compared. The sensitivity, specificity, positive and negative likelihood ratio, positive and negative predictive value, and accuracy of ultrasonography were calculated. Cohen's kappa coefficient was presented to assess the agreement of ultrasonography with OCT findings. Results: One hundred thirty patients with the mean age of 35.4±18.0 were evaluated (75.4% male). Sensitivity and specificity of ultrasonography were 84.6% (95% Cl: 53.7-97.3) and 98.3% (95% Cl: 93.3- 99.7), respectively. In addition, positive and negative likelihood ratio were calculated 49.5 (95% Cl: 12.3-199.4) and 0.15 (95% Cl: 0.04- 0.56), respectively. Cohen's kappa coefficient of 0.83 (95% Cl: 0.66-1.0; p<0.0001) was representative of excellent agreement of these two tests. Conclusion: The finding of this project was representative of 84.6% sensitivity, 98.3% specificity, and 96.9% accuracy of ultrasonography in detection of traumatic lens dislocation. It seems that in cases, which OCT is not possible, ultrasonography, could be an acceptable option to assess traumatic eye injuries.

Authors and Affiliations

Keywords

Related Articles

Rupture of Hydatid Liver Cyst into Peritoneal Cavity Following Blunt Abdominal Trauma; a Case Report

Hydatid cyst is a serious parasitic infection in places, which people has a close contact with dogs or sheep. They may be found as an incidental findings during routine clinical examination or even followed by radiograph...

Worsened Dysrhythmia after Chemical Cardioversion with Digoxin; a Case of Malpractice

The patient was a 23-year-old man referred to the emergency department (ED) with the chief complaint of palpitation. The patient experienced dizziness, cold sweating, and lightheadedness after getting up which started sp...

Pro-BNP versus MEDS Score in Determining the Prognosis of Sepsis Patients; a Diagnostic Accuracy Study

Introduction: Pro-brain natriuretic peptide (Pro-BNP) can act as an independent predictor of mortality in septic patients. This study aimed to compare the diagnostic accuracy of pro-BNP and Mortality in Emergency Departm...

Gastrointestinal Headache; a Narrative Review

There are studies reporting primary headaches to be associated with gastrointestinal disorders, and some report resolution of headache following the treatment of the associated gastrointestinal disorder. Headache disorde...

The Value of Serum NR2 Antibody in Prediction of Post-Cardiopulmonary Resuscitation Survival

Introduction: N-methyl-D-aspartate receptor subunits antibody (NR2-ab) is a sensitive marker of ischemic brain damage in clinical circumstances, such as cerebrovascular accidents. We aimed to assess the value of serum NR...

Download PDF file
  • EP ID EP321078
  • DOI -
  • Views 246
  • Downloads 0

How To Cite

(2014). Diagnostic Accuracy of Ultrasound in Detection of Traumatic Lens Dislocation. Archives of Academic Emergency Medicine, 2(3), 121-124. https://europub.co.uk/articles/-A-321078