Diastolic Electrocardiographic Parameters Predict Implantable Device Detected Asymptomatic Atrial Fibrillation

Journal Title: Balkan Medical Journal - Year 2017, Vol 34, Issue 5

Abstract

Background: Atrial fibrillation is the most common clinically significant arrhythmia. It is now established that atrial high-rate episodes are highly correlated with atrial fibrillation. Aims: To investigate the relation between diastolic electrocardiographic parameters and subclinical atrial fibrillation detected by cardiac implantable electronic devices. Study Design: Ccross-sectional study. Methods: A total of 203 patients who had a dual-chamber, rate-modulated pacing pacemaker implanted due to sinus node dysfunction were prospectively enrolled in this study. Atrial high-rate episodes were defined as any lasting more than 5 min with an atrial rate of ≥220 beats per minute during the previous year. Patient groups were categorized on the basis of pacemaker interrogation as the absence of atrial high-rate episodes [atrial high-rate episodes (-)] and the presence of atrial high-rate episodes [atrial high-rate episodes (+)]. Episodes related to atrial over sensing were excluded. Twelve-lead surface electrocardiography was independently analyzed by two experienced readers for the measurement of diastolic electrocardiography parameters. Results: Among 203 patients (mean age: 67.5±9.1, 60.1% male), 51 (25.1%) with atrial high-rate episodes were defined as group 1 and 152 (74.9%) without atrial high-rate episodes were defined as group 2. Both groups were similar in terms of demographic characteristics and cardiovascular risk factors. Tend-Q and Tend-P were significantly longer in group 2. PQ interval was statistically longer in group 1. Corrected QT interval was significantly longer in group 1. Diastolic electrocardiography index, heart rate and PQ and QT intervals were the only independent predictors of atrial high-rate episodes in patients with dual pacemakers in multivariate analysis. Conclusion: Abnormal diastolic electrocardiography parameters are powerful predisposing factors for the initiation of incident atrial fibrillation. Diastolic electrocardiography parameters and a novel diastolic index predict atrial high-rate episodes. Evaluating these parameters enables clinicians to identify patients who are at high risk and who may benefit from prophylactic treatment.

Authors and Affiliations

Ahmet İlker Tekkeşin, Yalçın Velibey, Ceyhan Türkkan, Ahmet Taha Alper, Yasin Çakıllı, Tolga Sinan Güvenç, Ozan Tanık, Adnan Kaya, Özlem Yıldırımtürk, Nazmiye Özbilgin, Özge Güzelburç, Ahmet Öz, Regayip Zehir, Kadir Gürkan

Keywords

Related Articles

Vincristine as an Adjunct to Therapeutic Plasma Exchange for Thrombotic Thrombocytopenic Purpura: A Single-Institution Experience

Background: Thrombotic thrombocytopenic purpura is a potentially life-threatening condition. Although the introduction of therapeutic plasma exchange has reduced mortality rates from over 90% to 10%-20%, approximately 40...

Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire

Background: Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the eff...

Rare Giant Angiokeratoma of the Vulva: A Case Report

Background: Angiokeratoma of fordyce occurring over on the vulva is a rare condition. Fordyce angiokeratoma is observed more frequently among men than women. In women, it is generally observed in later life, and appears...

Download PDF file
  • EP ID EP380503
  • DOI 10.4274/balkanmedj.2016.0246
  • Views 57
  • Downloads 0

How To Cite

Ahmet İlker Tekkeşin, Yalçın Velibey, Ceyhan Türkkan, Ahmet Taha Alper, Yasin Çakıllı, Tolga Sinan Güvenç, Ozan Tanık, Adnan Kaya, Özlem Yıldırımtürk, Nazmiye Özbilgin, Özge Güzelburç, Ahmet Öz, Regayip Zehir, Kadir Gürkan (2017). Diastolic Electrocardiographic Parameters Predict Implantable Device Detected Asymptomatic Atrial Fibrillation. Balkan Medical Journal, 34(5), 417-424. https://europub.co.uk/articles/-A-380503