Differences of Radiographic Quality and Exposure Index on Computed Radiography Using Imaging Plate with Different Reading Time Period

Journal Title: Journal of Medical Science And clinical Research - Year 2017, Vol 5, Issue 6

Abstract

ntroduction: Computed Radiography (CR) is the process of digitizing images using photostimulable plate to acquire image. The energy stored in the imaging plate disappears over the time, so imaging plate should be read as soon as possible to avoid the loss of image information. Objective: This study aimed at determining the profile of Exposure Index (EI), radiographic density and contrast on radiographs produced using CR with various reading time: 0 hours (without a break), 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22 and 24 hours after exposure. Methods: The type of research is observational study with cross-sectional design where data were collected by survey and analyzed using descriptive analysis. Result: The results showed that the profile of the exposure index (EI) value decreased irregularly. The average value of the highest and lowest EI on each object were 1394.33 and 1127.67 (cranium), 1871.33 and 1573.33 (elbow joint), while the largest percentage of degradation was at 22-hour reading time. Conclusion: The profile of radiographic density and contrast values varied at each lag time. The highest contrast were 1.24 (cranium) and 0.40 (elbow joint) that resulted at 0 hours lag time, whereas the lowest contrast value where 0.81 (cranium) and 0.34 (elbow joint) that resulted at 16 hours lag time. The image contrast was still editable till 10 hours lag time (cranium) and 12 hours lag time (elbow joint).

Authors and Affiliations

Arya Kurniawati

Keywords

Related Articles

Challenges of Clinical Psychology and Penitentiary System: Recidivism versus Reformation

Worldwide, prison system has been established to in incarcerate offenders with two fold objectives. One to segregate the convict from the society, and two to give him sufficient time to pore over repeatedly about his mis...

Evaluation of Single Dental Implant Replacement of Maxillary Second Premolar

Replacing a single tooth with an implant has become a common dental procedure. Through diagnosis and planning including the use of diagnostic cast and cone beam computed tomography scan can help the surgeons to predict t...

Role of Diagnostic Laparoscopy in non Specific Abdominal Pain

Background: Diagnostic Laparoscopy provides us with good view of whole peritoneal cavity there by clinching diagnosis. In General population Appendicular pathology is the leading etiology of non specific abdominal pain,...

Role of Cytology in Evaluation of Neck Swellings

Background: Neck swellings include various non-neoplastic and neoplastic lesions of lymph node, salivary gland, thyroid and soft tissue. Neoplasms of neck region account for majority of cancers in India, accounting for 2...

Teenage Pregnancy – An Unsafe Journey towards the Risky Destiny

Adolescence is defined as the period between 10 & 19 years by world health organisation. Adolescence is a critical period of biological & physiological changes. In India 4.3% of female deaths in this age group are relate...

Download PDF file
  • EP ID EP521998
  • DOI -
  • Views 68
  • Downloads 0

How To Cite

Arya Kurniawati (2017). Differences of Radiographic Quality and Exposure Index on Computed Radiography Using Imaging Plate with Different Reading Time Period. Journal of Medical Science And clinical Research, 5(6), 23664-23669. https://europub.co.uk/articles/-A-521998