Differential Protection of Power Transformer in Substation
Journal Title: International Journal of Trend in Scientific Research and Development - Year 2019, Vol 3, Issue 5
Abstract
Protection scheme required for the protection of power system components against abnormal conditions such as faults etc., and that essentially consists of protective relaying and circuit breaker. Protective relay senses the fault and determines the location of fault. Then, protective relay sends the tripping command to the circuit breaker. Therefore, proper care should be taken in designing and selecting an appropriate relay which is reliable, efficient and fast in operation. The voltage transformer and current transformer continuously measure the voltage and current of an electrical system and are responsible to give feedback signals to the relays to enable then to detect abnormal conditions. This paper describes differential protection for power transformer, especially the rating of purposed system is 100 MVA, 230 kV 33 kV at substation. Thida Win | Hnin Nandar Maung | Ye Min Hein "Differential Protection of Power Transformer in Substation" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd27995.pdfPaper URL: https://www.ijtsrd.com/engineering/electrical-engineering/27995/differential-protection-of-power-transformer-in-substation/thida-win
Text investigation for fine-grained object using Context technique
Fine-grained classification using recognized scene text in natural images. In this we extract the text from the image and the extracted text is translated to user known language by using language translator. We apply thi...
Storage of Biometric Data in Database
Storage of multi biometric information is required to encourage quick inquiry in expansive scale biometric frameworks. Past works tending to this issue in multi biometric databases concentrated on multi case ordering, fu...
Design and Simulation of 80 kHz High Frequency Converter Using CD 4047IC CMOS
English is a progressive study motivated by the intellectuals for the development of the national cultivation. English has then started its role in the educational field also. It enlarged its place in range of languages....
Effects of Reward on Performance of Workers in the Nigerian Public Sector
Service delivery in Nigeria's public sector has assumed greater significance given that much is required of the civil service if government is to successfully execute its policies and programmes. However, for effective a...
Preliminary Phytochemical Testing and Antimicrobial activity of Calotropis procera leaves.
Naturally found plants have become the boon to the field of herbal science and medicine. For the detection of bioactive principles present in the medicinally important plants, a preliminary screening of the phytochemical...