Diffusion Coefficient Measurements of T1-Enhanced Contrast Agents in Water Using 0.3 T Spin Echo Proton MRI
Journal Title: Nanomedicine & Nanotechnology Open Access - Year 2017, Vol 2, Issue 2
Abstract
The diffusion coefficients of four contrast agents (CAs, compounds of paramagnetic ions), Gd-DTPA, Gd-HP-DO3A, MnCℓ2, and albumin-(Gd-DTPA), in water were measured using 0.3 T proton MRI. The pixel size, number of signal averages (NSA), and scan time were 312 μm, four, and 6 min, respectively. Eight contrast solutions with initial paramagnetic ion concentrations (PCs) from 0.25 to 4.0 mmol/ℓ were added to eight rectangular grooves, 4 mm (the phase axis) × 1 mm (the frequency axis), in an agar gel electrophoresis plate. The diffusion motions of the CAs were revealed by the Gaussian concentration profiles along the frequency axis. The peaks of these profiles decreased with time, and their widths increased. The MRI signal profiles associated with the contrast solutions were proportional to and saturated with the PCs when the PCs were lower and higher than the saturation concentration of approximately 1 mmol/ℓ (just above the clinical dose), respectively. Thus, one hour after the start of diffusion, the signals whose initial concentration was neither too low nor too high exhibited normal Gaussian profiles that were not distorted by background noise or signal saturation. The diffusion coefficients of the CAs were determined by fitting the Gaussian concentration profiles to the normal Gaussian signal profiles. Although the sampling average of five image lines, summed along the phase axis, reduced irregularities in the signal profile, the coefficients determined reflected a measurement error of 10% because of the remaining irregularities produced by background noise. Increasing the NSA and decreasing the division along the phase axis are expected to reduce the measurement error without increasing the scan time, which is limited by the diffusion motion of the CA crossing the pixel size.
Authors and Affiliations
Osuga T, Ikehira H, Weerakoon B
The Effects of Moderate-Intensity Inhomogeneous Static Magnetic Fields on Neuromuscular Transmission
The present study focuses on the effects of moderate-intensity inhomogeneous static magnetic fields (SMF) up to 0.73 T on action potentials in Wistar rats. Thirty three animals were divided into three groups: a sham-expo...
Nanoanesthesia - A Novel Approach to Local Anesthesia Drug Delivery
A technique using anesthesia containing nanoparticles, drawn to the targeted areaof body by magnets provide a useful alternative to nerve block for local anesthesia. This technique in patients suggests an experimental st...
The Surface Property of Graphene
Since its first discovery in 2004 [1], graphene has attracted great interest due to its extraordinary properties [2-4], such as huge surface area, excellent mechanical strength, high flexibility, superb thermal and elect...
Relationships among Graphene, Zinc Oxide and Zinc Oxalate in Nanomedicine
The relationships among graphene (Gr), zinc oxide (ZnO), and zinc oxalate (ZnC2O4) are interpreted from the synthesis perspective. ZnC2O4 can be prepared using the dual-precursor sol-gel method, and can be regarded as th...
Self-Assembled O6-Succinyl Chitosan Nanoparticles for Controlled Release of Diosgenin and Agrochemicals
O6-succinyl chitosan was covalently linked to diosgenin and two synthetic brassinosteroid analogues with agrochemical and potential anticancer activity for their controlled release. FTIR and proton NMR spectroscopy confi...