Abstract

The paper presents a DSP-based system for measurement of the short-term transient distortions in electric power networks. These distortions typically possess short duration times and high amplitude values and thus they are very di.cult to acquire by standard digital data acquisition systems. We propose to apply an additional analog lowpass RC circuit before digital data acquisition. A properly chosen analog RC filter extends the duration time of transient distortion and simultaneously reduces its amplitude making it significantly simpler to acquire digitally. Next, digital signal processing is used for cancelling the analog convolution of the acquired signal with a RC filter. The paper discuses results obtained for di.erent con.gurations of the proposed measurement system including RC filter selection and digital deconvolution filter design. The algorithm was implemented in a Texas Instruments C617 DSK toolkit. Laboratory experiments with voltage signals are presented in the paper.

Authors and Affiliations

KRZYSZTOF DUDA, ANDRZEJ BIEŃ

Keywords

Related Articles

A NEURAL NETWORK BASED SYSTEM FOR SOFT FAULT DIAGNOSIS IN ELECTRONIC CIRCUITS

The paper considers the architecture and the main steps of development of a neural network based system for diagnosis of soft faults in analog electronic circuits. The definition of faults of interest, selection of an op...

LIFTING BASED COMPRESSION ALGORITHM FOR POWER SYSTEM SIGNALS

The paper concerns the problem of power system signals compression with possible application in system monitoring and control. The proposed compression algorithm for power system signals ensures efficient use of availabl...

INTRODUCTION TO THE T AND CHI-SQUARE DISTRIBUTION FOR A MORE ACCURATE EVALUATION OF THE MEASURE OF THE WORD ERROR RATE IN ANALOGTO-DIGITAL CONVERTERS<br />

The word error rate (WER) in an Analog to Digital Converter (ADC) is the probability of receiving an erroneous code for an input, after correction is made for gain, offset, and nonlinearity errors, and a specified allowa...

ON IMPROVEMENT OF SAMPLING TECHNIQUE DESIGNED FOR PRECISE ROOT MEAN SQUARE MEASUREMENTS<br />

A method for precise root mean square (RMS) measurement of periodic signals based on signal reconstruction is analysed. The RMS value of a signal under test is determined in three steps. In the first step, the Fourier co...

MULTITASKING MEASURING SYSTEM OF THE BACKING CALORIMETER FOR THE ZEUS EXPERIMENT AT THE HERA ACCELERATOR<br />

The paper is devoted to the subject of application of a complex measurement system in HEP experiments. The measurement system is electronic, FPGA-based, multi-channel and distributed. The application is the Backing Calor...