DIGITAL MEASUREMENT OF TRANSIENT DISTURBANCES IN ELECTRIC POWER NETWORK WITH ADDITIONAL LOWPASS ANALOG CIRCUIT<br />

Journal Title: Metrology and Measurement Systems - Year 2007, Vol 14, Issue 2

Abstract

The paper presents a DSP-based system for measurement of the short-term transient distortions in electric power networks. These distortions typically possess short duration times and high amplitude values and thus they are very di.cult to acquire by standard digital data acquisition systems. We propose to apply an additional analog lowpass RC circuit before digital data acquisition. A properly chosen analog RC filter extends the duration time of transient distortion and simultaneously reduces its amplitude making it significantly simpler to acquire digitally. Next, digital signal processing is used for cancelling the analog convolution of the acquired signal with a RC filter. The paper discuses results obtained for di.erent con.gurations of the proposed measurement system including RC filter selection and digital deconvolution filter design. The algorithm was implemented in a Texas Instruments C617 DSK toolkit. Laboratory experiments with voltage signals are presented in the paper.

Authors and Affiliations

KRZYSZTOF DUDA, ANDRZEJ BIEŃ

Keywords

Related Articles

PRE-PROCESSING AND PATTERN RECOGNITION METHODS FOR ARTIFICIAL OLFACTION SYSTEMS: A REVIEW

Data analysis is a fundamental part of artificial olfaction systems. Nonetheless, while electrical and mechanical components of electronic noses are deeply investigated and optimised for the specific applications, data a...

GIANT MAGNETORESISCANCE IN SPINTRONIC CO/PT NANOWIRE STRUCTURES

We used electrodeposition for growing of pure metallic, alloy and multilayer nanowires. Electrodeposition of cobalt/platinum nanowires was achieved in the cylindrical pores of a commercially available nuclear tracked pol...

ADVANCES AND GENERIC PROBLEMS IN INSTRUMENT DESIGN METHODOLOGY

The paper is based on a long-term programme of research on mathematical modelling and design of instruments and instrument elements in the Measurement and Instrumentation Centre of City University, London. It considers t...

TENTH ANNIVERSARY OF CHAIR OF ELECTRONIC AND PHOTONIC<br /> METROLOGY WROCŁAW UNIVERSITY OF TECHNOLOGY

This year the Chair of Electronic and PhotonicMetrology from Wrocław University of Technology celebrates its 10th anniversary. The Chair was established by the Senate of Wrocław University of Technology on January 27, 19...

HE INFLUENCE OF THE BALL MATERIAL ON THE BRINELL HARDNESS

A Brinell hardness tester with carbide and steel balls was calibrated and thereafter the hardness of ten samples of steel STN 41 1600 was measured by four appraisers. The uncertainty of calibration and of the hardness me...

Download PDF file
  • EP ID EP118658
  • DOI -
  • Views 58
  • Downloads 0

How To Cite

KRZYSZTOF DUDA, ANDRZEJ BIEŃ (2007). DIGITAL MEASUREMENT OF TRANSIENT DISTURBANCES IN ELECTRIC POWER NETWORK WITH ADDITIONAL LOWPASS ANALOG CIRCUIT<br /> . Metrology and Measurement Systems, 14(2), 283-291. https://europub.co.uk/articles/-A-118658