Distal Locking Jig Is a Use-Full Tool in Interlocking of Femur to Avoid the Use of Image Intensifier and Its Hazards: A Study

Journal Title: Scholars Journal of Applied Medical Sciences - Year 2015, Vol 3, Issue 6

Abstract

Diaphyseal fractures of femur are most common due to increase in road traffic accidents and fall from height from building constructions. Closed reduction or open reduction and intramedullary, interlocking ise surgical treatment of choice for the clean diaphyseal fractures. In most of the institutions image intensifier is used to perform the procedure and for the distal locking. Using distal locking jig avoids the usage of image intensifier and its hazards. Thirty cases of closed diaphyseal fracture of femur were managed with interlocking nail without using image intensifier and using distal locking jig for distal locking between May 2012 and December 2014. And post operatively we evaluated the accuracy of distal locking, using check x ray. The results were based on the postoperative radiological observations of the in all the thirty patients the single bolt was locked accurately using the distal locking jig in 19 mid diaphyseal fractures and in remaining 11 double distal bolts locking in distal third shaft fractures. We achieved 100% accuracy in distal locking using the distal locking jig. In conclusion Interlocking nailing using distal locking jig is an excellent tool for the distal locking for the diaphyseal fractures of femur. This reduces the hazards of image intensifier to the patient and surgical team. Keywords: Diaphyseal fracture, distal locking jig, Image intensifier, Interlocking nail.

Authors and Affiliations

Dr. Maruthi CV

Keywords

Related Articles

Clinico-Etiological Profile of Neurological Disorders in Hospitalized Children in Odisha

Abstract: A hospital based study of neurological disorders prevalent in children admitted to a tertiary care hospital. A total of 414 cases were studied and classified according to ICD-NA (1997) from G00-G99 after diagno...

Pattern of Soft Tissue Tumours in GMC Jammu- A one year Histopathological Study

Abstract: Soft tissue tumours constitute a large and heterogenous group of neoplasms. They are the mesenchymal proliferation that occurs in extraskeltalnonepithelial tissue of the body, excluding the viscera, covering of...

Comparison of Hypoglycemic Effects of Coscinium fensestratum colebr Bark and Stem in Normal Rats

This present study was conducted to evaluate the hypoglycemic effect of aqueous extract of stem and bark of Coscinium fensestratum colebr in normal rats. Total 18 rats were selected and divided into the three groups each...

Study on Bone Marrow Profile of Patients with Pancytopenia in a Tertiary Care Centre

Abstract: Pancytopenia is a common haematological entity that is characterized by the simultaneous presence of anemia, leukopenia and thrombocytopenia. A multitude of disorder primarily or secondarily affecting the bone...

Distal Locking Jig Is a Use-Full Tool in Interlocking of Femur to Avoid the Use of Image Intensifier and Its Hazards: A Study

Diaphyseal fractures of femur are most common due to increase in road traffic accidents and fall from height from building constructions. Closed reduction or open reduction and intramedullary, interlocking ise surgical t...