Distribution System Protection with Resistive Type SFCL during Intense Fault Conditions

Abstract

In this paper, a modified SFCL with extended resistance values for reduce the fault currents magnitude in the grid system was proposed. With the expansion in the benchmark estimation of the SFCL, the current is additionally reduced when contrasted with ordinary SFCL. The decreased values are looked at in this paper which represents the effectiveness of the proposed SFCL. Because of micro grid association with the power network, extreme current is a significant issue, to be explained for effective execution of micro grids. In any case, a deficiency of research concerning the area of SFCL in grid is felt. In this work, a resistive sort SFCL demonstrate was actualized by utilizing Simulink in Matlab as a stage. The outlined SFCL model could be effectively used for deciding an impedance level of SFCL as indicated by fault current of different sorts of grid. Additionally, grid transmission and distribution with network was displayed to decide the areaand the performance of the SFCL. The SFCL is introduced in IEEE 6 bus system with fault at different locations and observe the difference of fault current.

Authors and Affiliations

Rupali U. Pawar1, Pranita Chavan

Keywords

Related Articles

Operation Strategy of Electric Motors for Water Pumping On Malang City Regional Water Supply Company (Pdam Kota Malang) For Electrical Energy Efficiency Improvement

PDAM Kota Malang (Malang City Regional Water Supply Company) has several pumping stations that operate the water pump motors 24/7 with no breakdown period, while others operate the motors in rolling breakdown timing. Bad...

Power Quality Improvement Using Interleaved Boost Converter Fed Shunt Active Filter In Photo Voltaic System

Interleaved Boost Converter(ILBC) is a better converter between Photo Voltaic(PV) source and shunt active power filter. This paper deals with comparison of time domain outputs of PI and Fuzzy Logic controlled ILBC fed sh...

Retraining air Lines 220kv Transmission in The Paraguayan Power System using High Temperature conductors and Low Sag (HTLS) And Their Feasibility.

In the present study was assessed the technical and economic feasibility to change in high voltage aerial transmission lines conventional ACSR conductors by High Temperature and Low Sag (HTLS) conductors of similar diame...

Kitchen stove safety system using load cell

The purpose of this research paper is to create a safety system for the people using the kitchen stove. In today’s era the gas stoves are mainly working on LPG and electric system. The first gas stoves were developed in...

PSPICE Simulation For A Solar Panel To Understand Shading Effects

The present work is a study of the effects of partial shading on the performance of a PV module spatially on the maximum power point position. This search clarifies the mechanism of partial PV shading on a number of PV m...

Download PDF file
  • EP ID EP388363
  • DOI 10.9790/1676-1205021620.
  • Views 138
  • Downloads 0

How To Cite

Rupali U. Pawar1, Pranita Chavan (2017). Distribution System Protection with Resistive Type SFCL during Intense Fault Conditions. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(5), 16-20. https://europub.co.uk/articles/-A-388363