Dosimetric comparison and time consuming evaluations for neoadjuvant 5-fields versus 7-fields Intensity-Modulated Radiation Therapy for locally advanced rectal cancer.
Journal Title: JOURNAL OF ADVANCES IN PHYSICS - Year 0, Vol 7, Issue 2
Abstract
Aims and background: Preoperative multidrug - chemoradiotherapy schedule (PCR) is proven to be the standard approach in patients with locally advanced rectal cancer (LARC). The main limiting factor of PCR delivery is severe acute gastrointestinal (GI) toxicity due to the small bowel irradiated volume. Compared to 3-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiotherapy (IMRT) plans, with 7 or more fields, by highly conformal dose distributions, will minimize the dose received by small bowel, but required an increase in overall treatment time. The purpose of this study was to investigate if simple IMRT plans were comparable to conventional 7-fields IMRT in terms of dose distribution, with the advantage of reducing time delivery.Twelve patients with histologically proved LARC underwent PCR with concurrent chemotherapy with Oxaliplatin 50 mg/m2 intravenously weekly x 6 weeks + Capecitabine 1500 mg/mq day (on days 1,14 every 21 days) and 7-field IMRT step-and -shoot technique at the cumulative dose of 50.4 Gy to the target volume, with conventional fractionation schedule of 1.8 Gy each day. Dose calculation for selected Organ at Risks (OARs) such as femoral heads, bladder and small bowel, were performed. Without exceeding OARs dose constraints or compromising target coverage, for each treated patients, a simpleIMRT plan with 5 fields was computed and retrospectively compared with 7-field IMRT. Dosimetric parameters and treatment time data were analized. As expected, homogeneity of dose distribution was significantly better for 7F-IMRT than 5F-IMRT; while in terms of Conformation Number, as proposed by vant Riet et. Al, we registered no statistically significant differences between the two IMRT techniques resulting in equal sparing of healthy tissues. We recorded a median delivering treatment time of 7.9 minutes for 5F-IMRT and of 12.3 minutes for 7F-IMRT, with a difference statistically significant. This preliminary study demonstrated that the reduction in the number of fields obtained with the 5F-IMRT is a strategy to improve treatment time delivery without a detriment in target coverage and normal tissue sparing in PCR for LARC patients.
Authors and Affiliations
Alessia Reali
Electrodeposited MnO2- Carbon Cloth Supercapacitor Electrode Material for High Power Applications
Carbon cloth is a promising new material for the electrodes of supercapacitors, owing to their high surface area, flexibility, high conductivity with chemical stability. In this work, MnO2 was electrodeposited on a comme...
Action Flow in Obsessive-Compulsive Disorder Rituals: a model based on Extended Synergetics and a Comment on the 4th Law
The flow of actions in rituals of obsessive individuals is discussed from a nonlinear physics perspective. An amplitude equation model based on extended synergetics is studied. The amplitude dynamics describes both the b...
The Geometry of Space and Its Application to Theory of General Relativity, Derivation of Field Equations
In this paper we study the geometry of space and applications of this space to general theory of relativity. In space we obtained analog Ricci - Jacobi identity; the geodesic lines equation have been researched; we...
Global warming Vs Helium fusion in Sun
Global warming has been considered due to carbon dioxide emission and efforts are diverted to reduce the carbon dioxide emission. In this paper some different approach has been highlighted. In the Sun hydrogen fusion rea...
Homomorphisms and derivations on C*-ternary algebras assocoated with a generalized Cauchy-Jensen type additive functional equation
In this paper, we prove the generalized Hyers-Ulam stability of C∗-ternary homomorphisms and C∗-ternary derivations on C∗-ternary algebras associated with the generalized Cauchy-Jensen type additive functional equa...