Abstract

The purpose of the study was to evaluate the amount of radiation potentially absorbed by a pediatric patient during whole-head (13x15 cm) CBCT imaging compared with digital panoramic and lateral cephalometric imaging using the same machine. For each of the three imaging modalities, twenty-one nanoDot Optically Stimulated Luminescent Dosimeters (OSLDs) were placed in a pediatric anthropomorphic 10-year old phantom in order to record absorbed radiation doses at different radiosensitive locations. All imaging was performed using the manufacturer’s recommended exposure settings. Ten more runs were performed with an OSLD placed only at the thyroid. A Monte Carlo Analysis was performed to extrapolate the absorbed doses for the remaining twenty organ locations. Equivalent doses for the head and neck organs and overall effective doses was determined using the International Commission on Radiological Protection’s tissue weighting factor guidelines. For each of the organs tested, there was a statistically significant differences in radiation doses across the three imaging modalities. The highest radiation doses were observed in CBCT imaging for all organs. The average effective dose was higher in CBCT than in lateral ceph and panoramic imaging combined. The results of the study suggest that in order to reduce pediatric patient radiation exposure during routine orthodontic records, conventional 2D imaging with digital panoramic and lateral cephalometric modalities should be used preferentially over CBCT imaging.

Authors and Affiliations

AB Albin, AD Goren*, RD Faber, NK Anderson, LT Dauer, B Quinn, D Miodownik, K Kelly, I Branets, DC Colosi, M Mahdian

Keywords

Related Articles

Enhancement of Orthodontic Anchoring by the Use of Bone Anchorage: A Case Report

Orthodontic anchorage is the ability of a tooth or multiple teeth to resist unwanted reactional tooth movements, which could be provided by various means. The use of anchoring screws, or more precisely anchoring mini-scr...

Tooth Jewellery: Sparkle with Aurora of Dental Cosmos: An Overview

Tooth jewellery is an emerging trend in cosmetic dentistry, offering a novel and non-invasive means of personalizing one’s smile. This innovative practice involves the application of small, decorative gems or metals to t...

Current Understanding and Treatment Strategies of Peri-Implant Diseases - An Overview

As the general practitioners and specialists all over are placing dental implants with increased confidence and expertise, so are the diseases and complications associated with them have gained momentum. Peri-implant dis...

Gingival and Periodontal Diseases Seen in Children and Adolescents: A Review of Literature

Gingival and periodontal ontal disease are seen in children at various stages of their growth period. Although gingival diseases are fairly common in children it is the opposite for periodontal diseases. Periodontal dise...

There was a Time When Board Certification in Pediatric Dentistry Meant Something

As one reflects on their time on this planet, it’s become apparent that change is inevitable and conceptualization of what was once thought definitive carries new meaning and interpretation. In the political world, while...

Download PDF file
  • EP ID EP699015
  • DOI http://dx.doi.org/10.46889/JDHOR.2021.2201
  • Views 58
  • Downloads 0

How To Cite

AB Albin, AD Goren*, RD Faber, NK Anderson, LT Dauer, B Quinn, D Miodownik, K Kelly, I Branets, DC Colosi, M Mahdian (2021). Dosimetry Comparison of CBCT versus Digital 2D Orthodontic Imaging in a Pediatric Orthodontic Patient. Journal of Dental Health and Oral Research, 2(2), -. https://europub.co.uk/articles/-A-699015