Drug-Eluting vs. Bare-Metal Stents: Is it a Matter of Vessel Size?
Journal Title: UNKNOWN - Year 2017, Vol 7, Issue 6
Abstract
Background: Although drug-eluting stents (DES) for percutaneous coronary intervention have dramatically reduced the incidence of in-stent restenosis, their deployment for large-size coronary lesions is still controversial because of problems such as prolonged dual antiplatelet therapy, late in-stent thrombosis and costs. Aim: This study sought to evaluate the safety and effectiveness of drug-eluting stents (DES) compared to baremetal stents (BMS) for patients with large coronary vessels ≥ 3.5 mm. Methods: This is a retrospective case-control comparative study conducted in the cardiology A department of the university hospital Fattouma Bourguiba in Monastir. A total of 77 consecutive patients (80 lesions) who underwent, between October 2003 and March 2014, successfully DES implantation were compared to 73 consecutive patients (84 lesions) who were treated with BMS in large coronary vessels ≥ 3.5 mm. Results: The average age in our population was 59.7 ± 11.3 years with a male majority without any significant difference between the two groups. The DES group contained significantly more patients with diabetes (67.5% vs. 38.1%; p<0.0001) and a history of coronary heart disease (40% vs. 16.7%; p=0.001). The BMS group had significantly more procedures in the aftermath of MI (18.8% vs. 40.5%; p=0.002) including more primary angioplasty (6.7% against 47.1%; p=0.006). About two-thirds of the study patients had multi-vessel disease with equal distribution in both groups. The average duration of dual antiplatelet therapy was significantly prolonged in the DES group: 13.01 ± 8.31 months vs. 7.59 ± 8.19 months; p<0.0001. A mean follow of 27.87 ± 14.82 months was obtained. At 12 months, DES led to a significant reduction in the combined rate of major cardiac events by about 70% (OR=0.32; 95% CI: 0.119 to 0.858; p=0.019) without allowing a significant reduction in the rates of in-stent restenosis, in-stent thrombosis, target vessel revascularization or non-combined major cardiac events. During longterm follow-up, the benefit of DES in terms of MACE was maintained by allowing a 60% reduction in the combined rate of major cardiac events (OR=0.406; 95% CI: 0.172 to 0.955; p=0.035). Multivariate analysis identified the BMS as an independent predictor of major cardiac events and death. However, the type of stent does not appear as a factor influencing the ISR and target lesion revascularization rates. Conclusion: The results of our study demonstrate a clear clinical benefit of drug-eluting stents during angioplasty of large coronary arteries in reducing major cardiac events and death without having any effect on in-stent restenosis, in-stent thrombosis nor target lesion revascularization
Authors and Affiliations
Mohamed Mehdi Boussaada, Majed Hassine, Mejdi Ben Messaoud, Marouane Mahjoub, Zohra Dridi, Fethi Betbout
Being Principal Investigators on Pharma-initiated Clinical Trials: Have we Sold Ourselves Too Cheap?
The other day in clinic I was going through one of those good-clinical-practice (GCP) modules, as requested by one of the pharma companies in order for me to participate as an investigator in one of their clinical trial....
Improved Health-Related Quality of Life after Knee Arthroplasty Following an Outpatient Surgery Pathway: an Observational Comparative Case Study
Purpose: Enhanced recovery pathways after knee arthroplasty have been introduced worldwide with positive results. The present study investigated the improvements of health-related quality of life and functional outcome i...
A Combined and Intensive Exercise Model Improves Physical Capacity in Cardiac Patients
Objective: We have measured the effect of combined strength and high intensity endurance training on physical capacity and lipid profile in patients with heart and coronary diseases. We wanted to see whether cardiac pati...
Clinical Efficacy of Novel Filmogen, Antimicrobial, Cleaning, Fluidizing Cough Treatment
Objective: Cough reflex is the body’s protective mechanism to prevent entry of foreign material into the lower respiratory tract. Cough is usually caused by a primary viral infection: virus growth causes lysis of throat...
Efficacy and Tolerance of an Injectable Medical Device Containing Hyaluronic Acid and Amino acids: A Monocentric Six-Month Open-Label Evaluation
Background: An innovative injectable solution containing low molecular hyaluronic acid (HA) and a specific Amino Acids mixture was formulated to physiologically promote local neo-collagenesis and elastogenesis through fi...