Dynamic Analysis of Multi Storied Building with and without Shear Wall and Bracing

Journal Title: GRD Journal for Engineering - Year 2017, Vol 2, Issue 9

Abstract

Now a day the number of buildings are constructed and designed on the basis of architectural requirement and aesthetic view. Most of buildings are constructed in some spatial configuration like X shape, V shape with x and y co-ordinates non parallel to the structure. Earthquake is causing more damage to different configuration of building and their main problem is in the slenderness ratio. The main goal of this project is to make a comparative study of dynamic behavior of buildings with different configuration of structure in all seismic zones and different types of soils. In this study, a spatial configuration structure of 20stories up to 70m height of each storey height of 3.5m, with Shear wall and bracing at a different location in building is considered. The dynamic behavior of the building in all seismic zones II, III, IV, V and on different types of soil say hard, medium and soft soil was studied .The structure has outer periphery beams carrying R.C Shear wall of 200 mm thickness. The response spectrum analysis was carried out by using software of ETAB’s version 9.7.4.considering bracing and shear wall at a different location in the building. The following seismic parameters were analyzed and the behavior of the structure was studied in detail.

Authors and Affiliations

Sanjeev . , Prof. Lokesh. G, Prof. Sahebgouda Patil, Dr. Lingaraj Shastri

Keywords

Related Articles

Effect of Limestone Aggregate on High Strength Concrete in Both Fresh and Hardened States

Limestone is mainly constituent of chemical compound calcium carbonate (CaCo3). It is basically called sedimentary rock substance. As per researchers it forms 10% of total volume of Sedimentary rock. The extrusion & Impl...

Design of Active Voltage Regulator for Voltage Sag Mitigation

Power Quality (PQ) problems have obtained increasing attentions as they can affect lots of sensitive end-users. Studies indicate that voltage sags, transients and momentary interruptions constitute 92% of all the PQ prob...

Innovation in Construction Technology

The innovations originated in more than 20 countries, and cover all facets of construction, including design, fabrication, construction, rehabilitation, labor, management, equipment, and materials. From simple tools to c...

User Authentication using Keystroke Dynamics

There is need to secure sensitive data and computer systems from intruders while allowing ease of access for authenticating the user is one of the main problems in computer security. Traditionally, passwords have been th...

Urban Trip Rate Modeling for The Recently Expanded Areas: A Case Study of Surat

The rapid urbanization in our metropolitan cities has resulted in simultaneous expansion of cities in spatial dimension. The impact is also on the city infrastructure required for various sectors including transportation...

Download PDF file
  • EP ID EP227625
  • DOI -
  • Views 79
  • Downloads 0

How To Cite

Sanjeev . , Prof. Lokesh. G, Prof. Sahebgouda Patil, Dr. Lingaraj Shastri (2017). Dynamic Analysis of Multi Storied Building with and without Shear Wall and Bracing. GRD Journal for Engineering, 2(9), 44-51. https://europub.co.uk/articles/-A-227625