Ease of Intubation with the McGRATH® MAC, C-MAC® or Macintosh Laryngoscopes by Novice Operators in Simulated Difficult Airways – A Manikin Study

Journal Title: Journal of Advances in Medicine and Medical Research - Year 2016, Vol 16, Issue 8

Abstract

A variety of video laryngoscopes have been introduced to facilitate endotracheal intubations as failed intubations can result in morbidity and mortality. We aimed to compare the use of the conventional Macintosh laryngoscope, McGRATH® MAC and C- MAC® video laryngoscopes among novice operators. 37 medical students were recruited to perform oro-tracheal intubations in a human patient stimulator with simulated ‘difficult airway’ scenario using 3 devices: The Macintosh laryngoscope, McGRATH® MAC and C- MAC® video laryngoscopes. The success rate of tracheal intubation using the C-MAC® video laryngoscope (84%) was higher than both the McGRATH® MAC (59%) and the Macintosh laryngoscope (57%) (p=0.005). The use of video laryngoscopes were associated with lower incidence of oesophageal intubation (p<0.001) and deemed easier to use (p<0.001). Overall, the C-MAC® yielded a higher rate of successful tracheal intubation, a shorter time to glottic visualisation and was deemed to provide the greatest ease of intubation with novice practitioners.

Authors and Affiliations

L. Q. Liew, W. W. Teo, B. H. Tan, S. M. Leong, A. Y. Tan

Keywords

Related Articles

Evaluation of the Influence of Experimental Periodontitis on the Sexual Behaviour of Male Wistar Rats

Aim: Few studies have been reported a correlation between periodontal disease and erectile dysfunction in men. The aim of the present study was to evaluate the sexual behaviour of adult male rats with experimental period...

Microsatellite Instability within the CD30 Gene Promoter Distinguishes between Normal and Neoplastic Cells in Lymphoma

Aims: As differences in promoter activity and CD30 surface expression between CD30+ lymphoid cell-lines and peripheral blood leukocytes have been shown previously to be independent of the size of the CD30 promoter micros...

Alteration in Eosinophil’s Granular Content in Stained Film as an Index for Estimating the Shelf-lives of Modified Leishman Stains: Implications on Disease Diagnosis

Modified Leishman stain is a newly discovered stain which is composed of Leishman powder, absolute methanol and phenol. It is not ususual sometimes in diagnostic haematology laboratories to have improperly stained thin b...

Medical Practitioners and their Health: Doctors’ Personal Health Care Choices in Port Harcourt, Nigeria

Background: Doctors have a poor record of attending to their own health. Treatable conditions such as hypertension go unrecognised, health screening is avoided, and most doctors don’t have a general practitioner. This is...

Endarterectomy of the Totally & Subtotally Occluded Carotid Artery Facilitates the Surgery of the Stenosed Contralateral Side

Purpose: Patients with one side total/subtotal occlusion and contralateral side critical stenosis are high risk candidates for carotid interventions for the stenosed carotid side. We present our experiences with carotid...

Download PDF file
  • EP ID EP341538
  • DOI 10.9734/BJMMR/2016/27180
  • Views 39
  • Downloads 0

How To Cite

L. Q. Liew, W. W. Teo, B. H. Tan, S. M. Leong, A. Y. Tan (2016). Ease of Intubation with the McGRATH® MAC, C-MAC® or Macintosh Laryngoscopes by Novice Operators in Simulated Difficult Airways – A Manikin Study. Journal of Advances in Medicine and Medical Research, 16(8), 1-6. https://europub.co.uk/articles/-A-341538