Abstract

Objectives: To evaluate the effect of body position on intraocular pressure (IOP) measurement in the pediatric age group. Materials and Methods: Children whose general condition was healthy and ophthalmic examination was within normal limits were included. Forty-nine eyes of 49 pediatric patients were included in the study. IOP was measured with an ICARE rebound tonometer (ICARE PRO; ICARE, Helsinki, Finland) while patients were in standing, sitting, and supine positions. Differences between the consecutive measurements were compared statistically. Results: Twenty-two of the 49 patients were female, 27 were male. The mean age was 9.61±2.66 (5-15) years. Mean IOP values in the standing, sitting, and supine positions were 18.81±2.97 (11.6-26.2) mmHg, 18.88±3.44, (12-28.2) mmHg, and 19.01±2.8 (13.5-25.9) mmHg, respectively. There were no statistically significant differences in pairwise comparisons of the measurements taken in the different positions (p=0.846, p=0.751, p=0.606). There was a statistically significant correlation between corneal thickness and intraocular pressure values in all measurements (p=0.001, r=0.516). Conclusion: IOP values measured with the ICARE rebound tonometer in healthy children are not affected by body position.

Authors and Affiliations

Dilek Uzlu, Nurettin Akyol, Adem Türk, Nurcan Gürsoy, Ahmet Mehmet Somuncu, Yavuz Oruç

Keywords

Related Articles

Effect of Body Position on Intraocular Pressure Measured by Rebound Tonometer in Healthy Children

Objectives: To evaluate the effect of body position on intraocular pressure (IOP) measurement in the pediatric age group. Materials and Methods: Children whose general condition was healthy and ophthalmic examination wa...

Evaluation of the Effect of Proptosis on Choroidal Thickness in Graves’ Ophthalmopathy

Objectives: To evaluate the effect of proptosis on choroidal thickness in patients with Graves’ ophthalmopathy. Materials and Methods: Twenty-five eyes of 25 Graves’ patients with proptosis, 25 eyes of 25 Graves’ patien...

Evaluation of Diplopia Secondary to Seton Implantation Surgery: Ahmed Glaucoma Valve and Diplopia

Objectives: To determine and evaluate the rate of diplopia after Ahmed glaucoma valve (AGV) implantation surgery. Materials and Methods: The records of patients who underwent AGV implantation in our hospital between the...

In Vivo Confocal Microscopy and Anterior Segment Optical Coherence Tomography Findings in Two Cases with Mucopolysaccharidoses

The mucopolysaccharidoses are a group of disorders caused by inherited defects in lysosomal enzymes resulting in widespread intracellular and extracellular accumulation of glycosaminoglycans. Due to the mucopolysaccharid...

Download PDF file
  • EP ID EP689934
  • DOI 10.4274/tjo.galenos.2020.57702
  • Views 157
  • Downloads 0

How To Cite

Dilek Uzlu, Nurettin Akyol, Adem Türk, Nurcan Gürsoy, Ahmet Mehmet Somuncu, Yavuz Oruç (2020). Effect of Body Position on Intraocular Pressure Measured by Rebound Tonometer in Healthy Children. Turkish Journal of Ophthalmology, 50(5), -. https://europub.co.uk/articles/-A-689934