Abstract

A study of the effect of collimator thickness on the build-up factor value for the γ-radiation source has been conducted. The γ-radiation source used is from Cesium-137. The materials used in this research are concrete and wood, each of which was divided into 6 cm and 9 cm thickness. Data retrieval is done using Vernier Interface with Logger Pro 1.8 application. The data obtained are 600 radiation counts for each material thickness. The data processing of the enumeration results using inferential statistics is done to analyze the thickness of the collimator to the build-up factor value. The effect of the thickness of some of these materials is important to determine the value of build-up factor.The result obtained from the calculation is the build-up factor value increases along with the increasing thickness of the collimator for all materials. It is obtained that the build-up factor value is influenced by the thickness of the collimator. The B value for 6 cm & 9 cm wood collimator are 12,3% and 59,83% respectively while for 6 cm and 9 cm concrete collimator are 36,88% and 72,95% respectively, from B reference. The study of the build-up factor will be very useful in its application to the manufacture of radiation shields.

Authors and Affiliations

Panji P. Aji, Giner Maslebu, Suryasatriya Trihandaru

Keywords

Related Articles

Isolation of Organic Compounds from Medicinal Plant (Mimusops elengi) and Their Chemical Analysis

Medicinal plants are the rich source of unique phytochemicals which are frequently used in the development of drugs against various diseases. Mimusops elengi (Bakul) is usually known as medicinal plant f...

On Thermal Factor and MHD Mixed Convective Oscillatory Blood Flow in a Bifurcating Artery

Oscillatory blood flow in bifurcating arteries with emphasis on the thermal factor is investigated. Blood is treated as Newtonian, viscous, incompressible, homogeneous, magnetically susceptible, chemically reactive but o...

Evaluation of Adsorption Isotherms and Industrial Wastewater Treatment for COD Reduction Using Acid Impregnated Peanut Shell Activated Carbon

Phosphoric acid impregnated activated carbon has been successfully prepared from readily available agro waste (peanut shell) and applied in the treatment of industrial wastewater for reduction of organic matter contribut...

Nuclear Collisions Modeled with a Simple Piston-gas Model

A simple one-dimensional gas-piston kinetic model gives the interaction potential between two colliding heavy ions. In the frame of the classical, thermodynamical approach, the colliding heavy ions are not submitted to f...

Preparation of Polymer Nanofiber and Its Application

Today in the field of nanotechnology, polymer nanofiber have become a prominent area of research. They are widely used in wound healing, tissue engineering. Drug loaded biopolymer based nanofiber is used in wound healing...

Download PDF file
  • EP ID EP338802
  • DOI 10.9734/AJOPACS/2017/34467
  • Views 93
  • Downloads 0

How To Cite

Panji P. Aji, Giner Maslebu, Suryasatriya Trihandaru (2017). Effect of Collimator Thickness on Build-up Factor Value for γ-radiation Using Inferential Statistic. Asian Journal of Physical and Chemical Sciences, 3(3), 1-6. https://europub.co.uk/articles/-A-338802