Effect of Cyclic Loading on Abutment Screw Loosening in Angled Implant Abutments- An In-vitro Study

Journal Title: Journal of Clinical and Diagnostic Research - Year 2019, Vol 13, Issue 2

Abstract

ABSTRACT Introduction: Axis of loading can impact the effect of abutment fit to implant, thereby affecting the implant-abutment screw joint preload leading to screw loosening. Aim: The aim of the in-vitro study was to comparatively evaluate the effect of cyclic loading on abutment screw loosening of 25° angled premachined titanium abutments with that of 25° angled custom cast cobalt chromium (Co-Cr) abutments. Materials and Methods: Premachined titanium abutments (Group I) and custom cast cobalt-chromium abutments (Co-Cr) (Group II), 10 each of 25° angulation were connected to their respective titanium implants mounted in stainless steel blocks. Cement-cum-screw retained nickel-chromium cast crowns were fabricated. Abutment screws were torqued to 35 Ncm. Reverse torque values were measured using digital torque meter before and after cyclic loading simulating six months of function. The results were statistically analysed using Paired t-test and Independent t-test. Results: Mean pre-cyclic loading reverse torque values were 28.96 Ncm (Group I) and 26.01 Ncm (Group II) and mean post-cyclic loading reverse torque values were 25.84 Ncm (Group I) and 23.82 Ncm (Group II) respectively. Cyclic loading resulted in significantly lesser reverse torque values within both test groups (p<0.01). There was significantly greater loss of preload for Group II samples both prior to and after cyclic loading compared to Group I samples (p<0.01). Conclusion: Cyclic loading resulted in significant screw loosening within both test groups. Screw loosening was found to be significantly less for angled premachined titanium abutments than for angled custom cast Co-Cr abutments both before and after cyclic loading. The study is clinically significant regarding the importance of screw joint-abutment connection acting in a maxillary anterior implant region under load and the consequences of poor connection. The study is important in the aspect of clinical implications of angled implant abutments and the effect of loading on them.

Authors and Affiliations

Syed Ershad Ahmed, Chitra Shankar Krishnan, Jayashree Mohan, Parithimar Kalaignan

Keywords

Related Articles

A Curious Case of Pneumomediastinum caused after Diesel Aspiration

ABSTRACT Subcutaneous emphysema and Pneumomediastinum can occur as an uncommon complication of inhalation of irritant. It is a rare complication of hydrocarbon ingestion. There are many causative factors like oesophageal...

Metabolic Syndrome in Psoriasis among Urban South Indians: A Case Control Study Using SAM-NCEP Criteria

Introduction: Psoriasis is a chronic inflammatory disease of the skin associated with increased cardiovascular morbidity. Metabolic syndrome is a significant forecaster of cardiovascular events. Aim: To assess the associ...

A Rare Cause of Headache during Pregnancy

ABSTRACT Aneurysmal Subarachnoid Hemorrhage (SAH) during pregnancy is an important cause of maternal and fetal morbidity and mortality. Controversies still exist related to its diagnostic and treatment approach. This ar...

Portal Vein Pseudoaneurysm: A Rare Complication of Post Pancreaticoduodenectomy Haemorrhage

ABSTRACT Pancreaticoduodenectomy is a complex procedure which is associated with high rates of mortality and morbidity. With the improvement of surgical techniques and skills the mortality rates have come down drasticall...

Factors Hindering Practice of Day Care Surgery in a Tertiary Care Centre in Southern India: A Patient's Perspective

Introduction: Day care surgery offers cost containment, effective usage of hospital beds, reduced incidence of nosocomial infection and early recovery in home environment. In developing countries like India, there are va...

Download PDF file
  • EP ID EP579013
  • DOI 10.7860/JCDR/2019/37807.12585
  • Views 115
  • Downloads 0

How To Cite

Syed Ershad Ahmed, Chitra Shankar Krishnan, Jayashree Mohan, Parithimar Kalaignan (2019). Effect of Cyclic Loading on Abutment Screw Loosening in Angled Implant Abutments- An In-vitro Study. Journal of Clinical and Diagnostic Research, 13(2), 1-6. https://europub.co.uk/articles/-A-579013