Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base

Journal Title: Electronic Physician - Year 2017, Vol 9, Issue 5

Abstract

BACKGROUND: The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. AIM: To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. METHODS: This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. RESULTS: ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CONCLUSION: CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits

Authors and Affiliations

Lana Ahmed Shinawi

Keywords

Related Articles

Predictive values for procalcitonin in the diagnosis of neonatal sepsis.

Early diagnosis of neonatal sepsis followed by appropriate treatment decreases mortality and morbidity in infants. The aim of this study is to assess the role of procalcitonin (PCT) as a marker in the early diagnosis of...

Comparative Study of Vaginal versus Intramuscular Progesterone in the Prevention of Preterm Delivery: A Randomized Clinical Trial.

Preterm birth is a worldwide health concern due to its various negative consequences. Therefore, the prevention of preterm birth is a top priority for healthcare systems in all countries.

Genetic characterization of the wboA gene from the predominant biovars of Brucella isolates in Iran.

Brucella spp. are gram-negative, facultative intracellular bacteria pathogens responsible for brucellosis, a zoonotic disease that can cause abortion, fetal death, and genital infections in animals and undulant fever in...

Prevalence of depression and anxiety and their association with body mass index among high school students in Qazvin, Iran, 2013–2014

BACKGROUND: Evidence shows that mental disorders among adolescents are associated with suicide, drug abuse, acute infectious diseases and low educational performances. OBJECTIVE: To determine the prevalence of depressio...

Prevalence of hypocalcemia after phototherapy among neonates who underwent phototherapy in Koodakan Hospital in Bandar Abbas in 2013.

Hyperbilirubinemia is one of the most common problems in newborns, and it is reported in about 60% of infants. Phototherapy is used extensively to treat these patients, and hypocalcemia is one important side effect of th...

Download PDF file
  • EP ID EP321044
  • DOI 10.19082/4281
  • Views 78
  • Downloads 0

How To Cite

Lana Ahmed Shinawi (2017). Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base. Electronic Physician, 9(5), 4281-4288. https://europub.co.uk/articles/-A-321044