Effect of Dimensionless Number on Thermal Performance of Closed Loop Pulsating Heat Pipe: A Review

Journal Title: UNKNOWN - Year 2015, Vol 4, Issue 2

Abstract

" The objectives of this paper is to study effects of dimensionless numbers on thermal performance of the closed-loop pulsating heat pipe and to establish a correlation to predict the thermal performance of the closed loop pulsating heat pipe the heat pipes are made of long copper capillary tubes. Both ends were connected together to form a loop. Acetone, ethanol, methanol can be used as working fluids with constant filling ratio of 30 to 70 % by total volume. Thermal performance of closed loop pulsating heat pipe represented by Kutateladze number (Ku) and it depends on Prandtl number of liquid working fluid (Prl), Karman number (Ka), Bond number (Bo), Jacob number (Ja), and Aspect ratio (Le/Di). Moreover, thermal performance can be successfully established by analyzing all dimensionless numbers that have effect on the thermal performance of the closed loop pulsating heat pipe. "

Authors and Affiliations

Keywords

Related Articles

Design and Analysis of Energy Efficient Semi-Serial Link for On-Chip Communication

Now a days in network-on-chip (Noc) different type of communication links are used like parallel, serial and semi-serial links. In this project low energy semi-serial on-chip communication link is designed. In this proje...

CAMP: Cloud Assisted Mobile Health Care System with Privacy

A cloud storage system, consisting of a collection of storage servers, provides long-term storage services over the Internet. Storing data in a third party-s cloud system causes serious concern over data confidentiality....

Performance Evaluation of Power Saving Routing Protocol

There is tremendous increase in the applications which uses internet which results into affecting the network performance(QoS) because of heavy traffic load on the core routers which causes into more power requirements i...

Study the Quality Assurance of Conventional X-Ray Machine using Non-Invasive KV Meter

This study was carried out to obtain optimum operation conditions for X-ray machines. We investigated some factors affecting on quality assurance of conventional Siemen X-ray machine, in one of Mansoura Hospitals such a...

Central and Peripheral Sensitization in Patients with Chronic Shoulder Pain

Chronic shoulder pain present complex pathomechanical situations, frequent difficulties in identification of the pain causing factors leading to lack of effectiveness in treatment. Thus the purpose of this study is to i...

Download PDF file
  • EP ID EP353134
  • DOI -
  • Views 112
  • Downloads 0

How To Cite

(2015). Effect of Dimensionless Number on Thermal Performance of Closed Loop Pulsating Heat Pipe: A Review. UNKNOWN, 4(2), -. https://europub.co.uk/articles/-A-353134