Effect of Flow Pulsations on the Accuracy of Differential Pressure Flowmeters

Journal Title: Challenges of Modern Technology - Year 2017, Vol 8, Issue 1

Abstract

This work deals with investigation of influence of flow pulsation on the accuracy of gas flow rate and volume measurement by means of the differential pressure flow meters. Experimental studies of the step response curves of an impulse line with a pressure transducer (PT) were carried out with application of a high-frequency analog-to-digital converter of the pressure signal in the PT chamber. Mathematical model of an impulse line with a PT was built. This model provides simulation and investigation of the transient processes with high accuracy. The influence of the impulse line design (length, diameter) on the step response curves and on the frequency response curves as well as on the resonant frequency of the oscillating system (an impulse line with a PT chamber) was studied. The systematic errors of flow rate and volume measurement due to the resonance in the impulse lines which was caused by flow pulsation were simulated and studied for an acting differential pressure natural gas metering system. On the basis of the calculation results it was defined that amplification of the amplitude of the oscillating signal of the differential pressure due to the resonance may lead to a negative systematic error of gas volume measurement. The systematic errors of gas flow rate and volume measurement caused by the flow pulsation can be reduced by choosing the correct design of the impulse lines in order to avoid the resonance.<br/><br/>

Authors and Affiliations

Ihor Kostyk, Fedir Matiko, Roman Fedoryshyn

Keywords

Related Articles

Architecture of higher education in Poland in the context of sustainable development

The beginning of the 21st century was in Poland a period of intense investment activity in the development of infrastructure for higher education. University campuses have the potential to become an excellent model of ar...

Research on solvent systems with tetra-n-butylammonium bromide for counter-current chromatography of betalains

In this study, new two-phase solvent systems for counter-current chromatography (CCC) consisting of n-butanol and water as well as various amounts of acetic acid, acetonitrile, ethanol, acetone or ethyl acetate were test...

Tempo 30 – Noise Reduction and Synergy Effects

This article describes a noise reduction method applied in the German-speaking realm in Europe, the so-called Tempo 30 (T30) restriction that limits vehicular speed to 30 km per hour, and differentiates between T30 arran...

Analysis of applicability of porous concrete containing recycled ceramic aggregates for communication pedestrian routes forming surface rainwater drainage

This work is a continuation of the authors' research conducted to develop innovative concrete mixtures containing recycled ceramic aggregates formed after crushing of waste ceramic sanitary elements. The article presents...

Effect of the strong magnetic field on copper adsorption processes on activated carbon

In the presented studies an influence of the strong static magnetic field on the process of copper adsorption on activated carbon was analysed. The magnetic field was generated by the annular neodymium magnets, placed at...

Download PDF file
  • EP ID EP346613
  • DOI -
  • Views 38
  • Downloads 0

How To Cite

Ihor Kostyk, Fedir Matiko, Roman Fedoryshyn (2017). Effect of Flow Pulsations on the Accuracy of Differential Pressure Flowmeters. Challenges of Modern Technology, 8(1), 23-31. https://europub.co.uk/articles/-A-346613