Abstract

ndia is earthquake prone country and it is categorized into 4 seismic z ones II, III, IV, V, with respect to the cruelty of the earthquakes. Guidelines as per code I.S 1893 (part 1:2002) are beneficial for regular and small, low rise buildings. When it comes to tall buildings, every structure is analyzed in an individual aspec t. The response of building when dominate to seismic excitation can be classified in a number of ways. Structural analysis method can be mainly categorized into 4 methods are equivalent static, linear dynami c, non - linear static, non - linear dynamic. In the present paper is all about the effect of increasing height of building on design results. For analyzing the structure with th eir respective method static and dynamics analysis in terms of peak storey shear, base shear, lateral displacement, story drift and fundamental natural period. It includes modeling of ten cases of plan area 25m X 25m and the height is varied from 17.8m, 33.8m, 49.8m, 65.8m, 81 .8m were analyzed in which five cases of seismic zone IV are taken into account and compared with five other c ases of same configuration with seismic zone V. Models of different heights are developed with seismic zones IV and V in which G+4 and G+9 cases are analyzed with Fe 415, M25 and remaining G+14, G+19 G+24 cases are analyzed with Fe 500, M30 which is charac terized strength of concrete and grade of concrete and compared these cases in both seismic zones IV and V with medium type of soil. All ten cases of G+4, G+9, G+14, G +19 and G+24 were analyzed through STAAD Pro. V8i by using response spectrum method

Authors and Affiliations

Priyanka Varyani

Keywords

Related Articles

Dynamic Audit Services for Outsourced Storages in Clouds

In cloud, the security issue in outsourced storage data is the difficult challenge. To overcome the problem, traditional approach developed a dynamic audit service for verifying the integrity of an untr...

Effect of Sustainability Environmental Cost Accounting on Financial Performance of Nigerian C orporate O rganizations

This paper assesses the effect of sustainability accounting measure on the pe rformance of corporate organizations in Nigeria. Ex post facto research design and time series data were adopted. Data for stud...

Construction and Selection of Two Sided Complete Chain Sampling Plans - CCHSP (0 , 1) Indexed Through AOQL

In modern quality control prac tice, the professionals insist that if any defect occurs in a sample then very strict quality control measures should be adopted in order to avoid rejection. A novel algorithm for Chain Sam...

Building a New Organizational Design for Multinational Enterprise

This paper examined the modification in the conceptual frameworks which are used to understand and design MNEs. Disparity has been explored between traditional models and modern models which a...

Modified Fuzzy method for Vertical Handoff in Heterogeneous Networks

There are various types of networks in wireless technologies, having different parameters and their specifications and thus having different QoS (Quality of Service). So for moving the MS from...

Download PDF file
  • EP ID EP313753
  • DOI -
  • Views 110
  • Downloads 0

How To Cite

Priyanka Varyani (2017). Effect of Increasing Height of Building on Design Results. International Journal of Scientific Research and Management, 5(6), -. https://europub.co.uk/articles/-A-313753