Effect Of Location Of Lateral Force Resisting System On Seismic Behaviour Of RC Building

Journal Title: INTERNATIONAL JOURNAL OF ENGINEERING TRENDS AND TECHNOLOGY - Year 2013, Vol 4, Issue 10

Abstract

In this study the influence of location of lateral force resisting systems on the response reduction factor (R), ductility and plastic hinge status at performance point of the RC buildings were studded. The present paper made an attempt to study 4 types of 10 storey RC frame structure with different positions of shear wall on the symmetrical floor plans. Nonlinear pushover analysis has been performed using ETABS software in according with IS1893-2002. The actual values required for determination of response reduction factor (R), ductility and performance of the building are work out on the basis of pushover curve which is a plot of base shear verses roof displacement and pushover curve gives the actual capacity of the structure in the nonlinear rang. The results show that due to transfer the shear wall to the inner core, response reduction factors (R) and ductility reduce, but the number of plastic hinges beyond collapse increase. So it is essential to consider the effect of shear wall shifting for the seismic evaluation of RC buildings.

Authors and Affiliations

Mohammad Parsaei Maram , Dr. K Rama Mohana Rao

Keywords

Related Articles

 A Review: CEST Method Based Analysis for the Detection of Damaged Buildings in Crisis Areas

 This paper describes new combined method that consists of a cooperative approach of several different algorithms for automated change detection. Remote sensing data are primary sources extensively used for change d...

High Speed Matrix Multiplication Implementation Using Field Programmable Gate Array

Matrix operations are commonly used in almost all areas of scientific research. Matrix multiplication has significant application in the areas of graph theory, numerical algorithms, signal processing, and digital control...

 Architectural Level Power Optimization Techniques for Multipliers

 — In this work, a new topology was proposed to optimize the power dissipation of Multipliers. Low power digital Multiplier Design based on bypassing techniquemainly used to reduce the switching power dissipation. W...

Peak Monitoring the Egotistic Nodes in MANET During Duplication Allocation

Mobile Ad Hoc Network is a collection of mobile hosts. The mobility nature of the MANET causes the mobile host to move freely in the network, due to that network disconnections occurs frequently and this causes frequent...

Design and Construction of a Simple but Efficient and Cost Effective Amplitude Modulated Transmitter Using Locally Available Materials

This work is an exploration of the design foundation and construction of an AM Transmitter. An AM transmitter controls the transmitting and broadcasting of signals that supports information conveyance in the AM Bandwidth...

Download PDF file
  • EP ID EP136181
  • DOI -
  • Views 120
  • Downloads 0

How To Cite

Mohammad Parsaei Maram, Dr. K Rama Mohana Rao (2013). Effect Of Location Of Lateral Force Resisting System On Seismic Behaviour Of RC Building. INTERNATIONAL JOURNAL OF ENGINEERING TRENDS AND TECHNOLOGY, 4(10), 4598-4603. https://europub.co.uk/articles/-A-136181