Effect of Repeated Bonding on the Shear Bond Strength of Smartbond Cyanoacrylate Orthodontic Adhesive

Journal Title: IP Annals of Prosthodontics and Restorative Dentistry - Year 2016, Vol 2, Issue 1

Abstract

Cyanoacrylate adhesive material is known to be used as superglue material in fields of dentistry and medicine for years. Moisture insensitivity has rendered the adhesive material useful as orthodontic bonding agent in cases where isolation is difficult. This study was undertaken to measure Shear Bond Strength with Smartbond first bonding and after debonding and repeated bonding twice. 30 test specimens were prepared from extracted maxillary and mandibular premolar teeth, which were subjected to repeat bonding (2 repetitions) using Smartbond and Shear Bond Strength was measured for each of them. Mean Shear Bond Strength of 6.13 MPa ± 2.30 was obtained after first bonding. Mean Shear Bond Strength of 4.17 MPa ± 2.44 and 4.18 MPa ± 1.49 was obtained after first and second rebonding respectively. Smartbond shows optimal Shear Bond Strength at initial bonding but shows Shear Bond Strength to be inadequate after first and second debonding rebonding procedures.

Authors and Affiliations

Shivam Mehta, Falguni Mehta, Renuka Patel, Ashish Kumar

Keywords

Related Articles

Comparative Assessment of Torque Expression of Stainless Steel, Nickel Titanium, Heat Activated Nickel Titanium and Titanium Molybdenum Alloy Wires - A Finite Element Method Study

Objective: To assess and compare the torque values of different wires - Stainless Steel, Nickel Titanium, Heat Activated Nickel Titanium and Titanium Molybdenum alloy using Finite Element Analysis. Methods: Three-dimensi...

Prosthesis for mandibular guidance therapy – A case series

This article shows the importance of an intraoral guiding flange prosthesis in patients who have undergone resection of mandible due to an underlying pathology The case series show how the use of a guidance prosthesis ca...

CAD-CAM the future of digital dentistry: a review

CAD/CAM called as Computer Aided Design/Computer Aided Manufacturing was introduced to dentistry in the mid-1980s. CAD/CAM restoration fabrication is available as both chairside and chair side—laboratory integrated. In t...

Auricular prosthesis: A ray of hope

The absence of an associated part of an ear may be a considerable aesthetic drawback which affects the patient’s scientific discipline and social behaviour. Prosthetic rehabilitation of auricular defects is often a deman...

Osteoporosis: A silent disease affecting endentulous patients at an alarming rate

Osteoporosis has evolved as the major bone disease characterized by weak and fracture prone bones. Osteoporosis is a “silent disease” because bone eventually becomes porous, brittle and thus making it abnormally vulnerab...

Download PDF file
  • EP ID EP243384
  • DOI -
  • Views 44
  • Downloads 0

How To Cite

Shivam Mehta, Falguni Mehta, Renuka Patel, Ashish Kumar (2016). Effect of Repeated Bonding on the Shear Bond Strength of Smartbond Cyanoacrylate Orthodontic Adhesive. IP Annals of Prosthodontics and Restorative Dentistry, 2(1), 14-18. https://europub.co.uk/articles/-A-243384