Effect of storage temperature and time on coagulation factor after cryoprecipitated antihemophilic factor melting

Journal Title: Chinese Journal of Blood Transfusion - Year 2024, Vol 37, Issue 4

Abstract

Objective To study and compare the effects of different storage temperature and time on coagulation factor after cryoprecipitated antihemophilic factor(CAF) melting, and to provide reference for the establishment of industry standards. Methods From June 2021 to May 2023, a total of 96 bags of CAF were sampled in 4 bags per month, and timely detected in the same month. After the CAF was melted in a 37℃ water bath, the mild to moderate lipemic blood was labeled. Each bag of CAF and two 50 mL transfer bags were divided into two bags and two groups of 20 mL each using a sterile adapter. One group was placed in a 4℃ refrigerator and the other in a 22℃ water bath for 0 h, 4 h, 8 h, 12 h, 24 h and 48 h. Then 2 mL of aseptic sample was taken separately and put into the test tube, and 1mL of sample and 3 mL of buffer were added into the other test tube with the sampling gun and mixed on the machine for testing. The experimental data of 60 bags without mild to moderate lipemic blood cryoprecipitation and coagulation factor were randomly selected and statistically analyzed by SPSS21.0. Results After melting, CAF was stored for 0 h, 4 h, 8 h, 12 h, 24 h and 48 h to detect the average content and growth rate of coagulation factor in the two groups: 1) Storage at 4℃, factor Ⅷ content was 118.62, 111.57(-5.95%), 105.51(-11.05%), 103.30(-12.92%), 94.35(-20.46%) and 83.25(-29.82%) IU/ bag, respectively; Storage at 22℃, the factor Ⅷ content was 118.62, 112.69(-5.00%), 111.41(-6.08%), 109.01(-8.10%), 101.55(-14.39%) and 92.75(-21.81%) IU/ bag, and the storage results of the two groups were compared. At 24 h at 4℃ and 48 h at 22℃, the content of factor Ⅷ had significant statistical significance(P<0.01), and when stored at 22℃, the decay rate of factor Ⅷ was slower; 2) When stored at 4℃, the content of factor V was 41.19, 41.31(0.29%), 40.52(-1.64%), 40.27(-2.23%), 39.05(-5.19%) and 36.99(-10.21%) IU/ bag, respectively; Stored at 22℃, the factor V content was 41.19, 41.71(1.25%), 42.54(3.28%), 41.94(1.80%), 39.21(-4.80%) and 35.64(-13.48%) IU/ bag, respectively. Comparison of storage results between the two groups showed that the content of factor V was statistically significant(P<0.05) and significantly significant(P<0.01) at 4℃48 h and 22℃48 h, respectively, and the decay rate of factor V was faster when stored at 22℃; 3) When stored at 4℃, the Fbg content was 268.86, 268.17(-0.26%), 262.46(-2.38%), 270.50(0.61%), 267.52(-0.50%) and 261.92(-2.58%) mg/ bag, respectively; Stored at 22℃, the Fbg content was 268.86, 265.86(-1.12%), 264.12(-1.77%), 265.89(-1.11%), 266.04(-1.05%) and 261.04(-2.91%) mg/ bag, respectively. There was no statistical significance between the 2 groups and the original 0 h content in each time period(P>0.05). Conclusion After CAF melting, coagulation factor decreased with the extension of storage time, especially the decrease of factor Ⅷ, followed by factor V, while Fbg basically unchanged. Comparison between the two groups showed that, factor Ⅷ decay rate is slower, factor V decay rate is faster of storage at 22℃. CAF should be transfused as soon as possible after melting. If the delay is unavoidable, for the delay time less than 12 h, storage at 4℃ is recommended, fot the delay time more than 12 h and less than 24 h, storage at 22℃ is recommended.

Authors and Affiliations

Yuan WANG, Guoying LIU, Dawei KONG, Jianbin LI, Xinli JIN, Yuhong ZHANG, Wenchao GE, Lin CHENG, Jiaxuan LIU, Yuzhen LIU

Keywords

Related Articles

Establishment of Shaanxi rare blood group information supply platform

Objective To establish a rare blood group information supply platform in Shaanxi Province. Methods The rare blood group information supply platform consists of sample registration, result registration, donor files and in...

Frequency survey of blood group PP1PK in Chinese Lahu Population

Objective To investigate the frequency of P1PK and GLOB blood group in Chinese Lahu population and their genetic status, so as to provide data support for the safety of blood transfusion and give advice and transfusion g...

Dentification and blood transfusion therapy of anti-C, e alloantibodies with anti-e, Jkb mimicking alloantibodies

Objective To investigate the differential diagnosis of 1 anti-C, e alloantibodies combined with anti-e, Jkb mimicking alloantibodies by absorption-elution test and titer integral method. Methods ABO, Rh and Kidd blood gr...

Progress in plasma exchange for severe immune-related dermatoses

Plasma exchange (PE) is effective in a part of autoimmune diseases, and its main action mechanisms include removing pathogenic factors from the patient's blood, regulating immune function, replenishing normal plasma comp...

Effect of adding tranexamic acid during surgery on blood loss and security during short segment lumbar spinal stenosis surgery

Objective To discuss the effect of adding tranexamic acid(TXA) during surgery on blood loss and security during short segment lumbar spinal stenosis surgery. Methods One hundred and eight patients with lumbar spinal sten...

Download PDF file
  • EP ID EP738799
  • DOI 10.13303/j.cjbt.issn.1004-549x.2024.04.009
  • Views 6
  • Downloads 0

How To Cite

Yuan WANG, Guoying LIU, Dawei KONG, Jianbin LI, Xinli JIN, Yuhong ZHANG, Wenchao GE, Lin CHENG, Jiaxuan LIU, Yuzhen LIU (2024). Effect of storage temperature and time on coagulation factor after cryoprecipitated antihemophilic factor melting. Chinese Journal of Blood Transfusion, 37(4), -. https://europub.co.uk/articles/-A-738799