Effect of Technique of Disinfection by Ultrasonic Nebulization on Accuracy of Vinyl Polysiloxane Impressions

Journal Title: Journal of Clinical and Diagnostic Research - Year 2019, Vol 13, Issue 8

Abstract

ABSTRACT Introduction: To prevent cross-contamination, impressions should be properly disinfected after removing from the mouth. To be efficacious, a successful disinfection must maintain the physico-chemical properties of the impression materials and should not interfere negatively in the fabrication of stone casts. Aim: To evaluate the effect of different disinfection techniques on the accuracy of dental impressions made of vinyl polysiloxane. Materials and Methods: 40 test samples made of vinyl polysiloxane were obtained using a pattern cylinder. The samples were randomly divided into 5 experimental conditions: I-Control, impressions without any disinfection, II-Immersion in 2% glutaraldehyde for 10 minutes, III-Immersion in 0.2% peracetic acid for 10 minutes, IV-ultrasonic nebulization for 10 minutes in 2% glutaraldehyde and V-ultrasonic nebulization for 10 minutes in 0.2% peracetic acid. The impressions obtained were poured in type IV gypsum and both the height and diameter of the stone casts were measured. For this purpose a profile projector joined to a digital measurement system was used. The data were submitted to statistical analysis using Bioestat 5.3 software. The Shapiro-Wilk test was applied to assess normal data distribution. Data were analysed by one-way ANOVA and Tukey’s test for comparisons of the means of the different groups, p-value less than 0.05 was considered as statistically significant. Results: Groups I, II and III did not differ statistically among themselves, both in diameter and height. Group IV presented statistically different results from the others for diameter. Whereas for height, the results were shown to be similar among groups I, II, III and IV. For Group V, the results obtained were statistically different for both height and diameter from those of the other groups. Conclusion: The immersion technique did not interfere in the accuracy of the stone casts however the ultrasonic nebulization with 2% glutaraldehyde solution did not show significant differences for height and presented better values of dimensional accuracy in diameter, when compared to the control group. The ultrasonic nebulization method associated with 2% peracetic acid solution presented the worst dimensional accuracy values for height and better values for the diameter compared to the other groups.

Authors and Affiliations

Luana Caroline Piva, Jamille Favarão, Mauricio Matte Zanini, Veridiana Camilotti, Marcio Jose Mendonca, Mario Alexandre Coelho Sinhoreti

Keywords

Related Articles

A Comparative Evaluation of Accuracy of the Dies Affected by Tray Type, Material Viscosity, and Pouring Sequence of Dual and Single Arch Impressions- An In vitro Study

Introduction: The clinician’s skill, impression techniques, and materials play a very important role in recording fine details in an impression for accuracy of fixed partial denture prosthesis. Impression of prepared tee...

Plasma Cell Disorders in HIV Infected Patients: A Case Series

People Living with HIV (PLHIV) are at an increased risk of developing malignancies. Plasma cell disorders are also reported with increased incidence in PLHIV compared to the general population. Here, we describe three di...

Detection of blaCTX-M Extended Spectrum Beta-lactamase Producing Salmonella enterica Serotype Typhi in a Tertiary Care Centre

Introduction: Infections caused by Salmonella are an important public health threat in tropical and subtropical countries. Due to the emergence of resistance to ampicillin, chloramphenicol and trimethoprim/sulfamethoxazo...

Assessment of Vitamin D Receptor Gene Polymorphism in Iraqi Women with Polycystic Ovary Syndrome

ABSTRACT Introduction: Polycystic Ovary Syndrome (PCOS) is the most common hormonal disorder in women that occurs mainly in the reproductive age. It is suggested to be highly complex and heterogeneous disorder with an u...

Foetal Magnetic Resonance Images of Two Cases of Aicardi Syndrome

Cerebral malformations are of fundamental importance in the clinical diagnosis of Aicardi Syndrome (AS). Some of these anomalies like callosal agenesis, cysts formation, posterior fossa anomalies and gross interhemispher...

Download PDF file
  • EP ID EP639325
  • DOI 10.7860/JCDR/2019/40849.13056
  • Views 117
  • Downloads 0

How To Cite

Luana Caroline Piva, Jamille Favarão, Mauricio Matte Zanini, Veridiana Camilotti, Marcio Jose Mendonca, Mario Alexandre Coelho Sinhoreti (2019). Effect of Technique of Disinfection by Ultrasonic Nebulization on Accuracy of Vinyl Polysiloxane Impressions. Journal of Clinical and Diagnostic Research, 13(8), 1-4. https://europub.co.uk/articles/-A-639325