Effectiveness of NaF Vials for Estimation of Glucose in NABL Accrediated Laboratory of a Tertiary Care Hospital

Journal Title: Scholars Journal of Applied Medical Sciences - Year 2018, Vol 6, Issue 10

Abstract

Comparison of glucose level in NaF vacutainer and serum separator vacutainer. The study was conducted at Biochemistry Department of Himalayan Institute of Medical Sciences, Dehradun, Uttarakhand. Total 386 random cases were selected for the study. Glucose levels were measured by the Hexokinase method using a Unicel DXC800 Chemistry analyser (Beckman Coulter India (Pvt.) Ltd.). “Paired t- test” was used for analysis. No significant difference of glucose values were seen amongst the two vacutainers, whereas a significant decrease in glucose levels with time was observed in both the vacutainers statistically. Serum separator vacutainers can be used in place of NaF vacutainers to estimate glucose in the clinical laboratories.

Authors and Affiliations

Dr. Anita Sharma, Dr. A. D Deepak, Dr. Vinita Kalra

Keywords

Related Articles

Endoscopic Evaluation of Patients Presenting with Heartburn

Gastroesophageal reflux disease (GERD) is a common disorder affecting a large section of the community. In addition, the numerous complications of chronic GERD especially Barrett’s oesophagus necessitate adequate diagnos...

Utilization of immunization services in a tertiary care center

Abstract: Vaccination is one of the most cost effective specific protections for child survival. Government of India is committed to safeguard all newborns and infants from the common vaccine preventable diseases by immu...

Comparison of Polyglactin 910 Rapide versus Chromic catgut for episiotomy repair

With the objective of comparing the efficacy of polyglactin 910 rapide in continuous locking technique versus chromic catgut in interrupted technique for episiotomy repair regarding perineal pain, analgesic requirement,...

A Prospective Study of Patellar Fracture Complications

Abstract: Patellar fractures are common and constitute about 1% of all skeletal injuries and results because of direct trauma, which causes more comminution whereas indirect injury leads to more displacement with transve...

A Cross-Sectional Study on Patient Satisfaction with Hospital Services From The Outpatient Department of Tertiary Care Hospital, Adilabad, Telangana State

Patient satisfaction is an important means of measuring the effectiveness of health care delivery and quality of medical care. It denotes the extent to which general health care needs of the patient are met with their re...

Download PDF file
  • EP ID EP478377
  • DOI -
  • Views 63
  • Downloads 0

How To Cite

Dr. Anita Sharma, Dr. A. D Deepak, Dr. Vinita Kalra (2018). Effectiveness of NaF Vials for Estimation of Glucose in NABL Accrediated Laboratory of a Tertiary Care Hospital. Scholars Journal of Applied Medical Sciences, 6(10), 3722-3724. https://europub.co.uk/articles/-A-478377