Effects of Device and Formulation on In Vitro Performance of Dry Powder Inhalers

Journal Title: The AAPS Journal - Year 2012, Vol 14, Issue 3

Abstract

The study examined the sensitivity of DPI in vitro performance to formulation and device changes. Rotahaler/Rotacaps was selected as the reference DPI drug product, and Aerolizer was selected as the test device. Since the test device was recognized to have much greater efficiency of dispersion, simple modifications to both formulation and device were made in an effort to provide a closer match to the in vitro performance of the reference product. The modifications included varying the drug and lactose particle sizes and/or lactose fine particle content in the test formulations, as well as lowering the specific resistance of the test device. These modifications were intended to address variables important for drug product performance for a defined experimental design and were not intended to mimic the extensive formulation and device design strategies that are employed in an industrial setting. Formulation and device modifications resulted in a modified test product that approached the reference product in the in vitro performance.

Authors and Affiliations

Wallace P. Adams, Sau L. Lee, Robert Plourde, Robert A. Lionberger, Craig M. Bertha, William H. Doub, Jean-Marc Bovet, Anthony J. Hickey

Keywords

Related Articles

Harmonization of Regulatory Approaches for Evaluating Therapeutic Equivalence and Interchangeability of Multisource Drug Products: Workshop Summary Report

Regulatory approaches for evaluating therapeutic equivalence of multisource (or generic) drug products vary among different countries and/or regions. Harmonization of these approaches may decrease the number of in vivo b...

Anti-HIV Drug Development Through Computational Methods

Although highly active antiretroviral therapy (HAART) is effective in controlling the progression of AIDS, the emergence of drug-resistant strains increases the difficulty of successful treatment of patients with HIV inf...

Effective Absorption Modeling in Relative Bioavailability Study Risk Assessment

Absorption modeling is an excellent strategic fit to perform a risk assessment for relative bioavailability (RBA) studies as it provides direct input into the question that is at the core of the RBA decision, namely, how...

In Vitro Studies are Sometimes Better than Conventional Human Pharmacokinetic In Vivo Studies in Assessing Bioequivalence of Immediate-Release Solid Oral Dosage Forms

Human pharmacokinetic in vivo studies are often presumed to serve as the “gold standard” to assess product bioequivalence (BE) of immediate-release (IR) solid oral dosage forms. However, when this general...

Download PDF file
  • EP ID EP681229
  • DOI  10.1208/s12248-012-9352-7
  • Views 70
  • Downloads 0

How To Cite

Wallace P. Adams, Sau L. Lee, Robert Plourde, Robert A. Lionberger, Craig M. Bertha, William H. Doub, Jean-Marc Bovet, Anthony J. Hickey (2012). Effects of Device and Formulation on In Vitro Performance of Dry Powder Inhalers. The AAPS Journal, 14(3), -. https://europub.co.uk/articles/-A-681229