Effects of Device and Formulation on In Vitro Performance of Dry Powder Inhalers

Journal Title: The AAPS Journal - Year 2012, Vol 14, Issue 3

Abstract

The study examined the sensitivity of DPI in vitro performance to formulation and device changes. Rotahaler/Rotacaps was selected as the reference DPI drug product, and Aerolizer was selected as the test device. Since the test device was recognized to have much greater efficiency of dispersion, simple modifications to both formulation and device were made in an effort to provide a closer match to the in vitro performance of the reference product. The modifications included varying the drug and lactose particle sizes and/or lactose fine particle content in the test formulations, as well as lowering the specific resistance of the test device. These modifications were intended to address variables important for drug product performance for a defined experimental design and were not intended to mimic the extensive formulation and device design strategies that are employed in an industrial setting. Formulation and device modifications resulted in a modified test product that approached the reference product in the in vitro performance.

Authors and Affiliations

Wallace P. Adams, Sau L. Lee, Robert Plourde, Robert A. Lionberger, Craig M. Bertha, William H. Doub, Jean-Marc Bovet, Anthony J. Hickey

Keywords

Related Articles

CYP3A4 Mediates Oxidative Metabolism of the Synthetic Cannabinoid AKB-48

The online version of this article (doi:10.1208/s12248-015-9788-7) contains supplementary material, which is available to authorized users.

Appropriate calibration curve fitting in ligand binding assays

Calibration curves for ligand binding assays are generally characterized by a nonlinear relationship between the mean response and the analyte concentration. Typically, the response exhibits a sigmoidal relationship with...

Impact of Data Base Structure in a Successful In Vitro-In Vivo Correlation for Pharmaceutical Products

The in vitro-in vivo correlation (IVIVC) (Food and Drug Administration 1997) aims to predict performances in vivo of a pharmaceutical formulation based on its in vitro characteristics. It is a complex process that (i) in...

Erratum to: Autoradiography, MALDI-MS, and SIMS-MS Imaging in Pharmaceutical Discovery and Development

This article was published with incorrect reference citations in the permission notes in the legends for Figures  8 and 9. The permission note for Figure 8 should read: (Adapted with permission from Ref....

Role of the breast cancer resistance protein (ABCG2) in drug transport

The 72-kDa breast cancer resistance protein (BCRP) is the second member of the subfamily G of the human ATP binding cassette (ABC) transporter superfamily and thus also designated as ABCG2. Unlike P-glycoprotein and MRP1...

Download PDF file
  • EP ID EP681229
  • DOI  10.1208/s12248-012-9352-7
  • Views 57
  • Downloads 0

How To Cite

Wallace P. Adams, Sau L. Lee, Robert Plourde, Robert A. Lionberger, Craig M. Bertha, William H. Doub, Jean-Marc Bovet, Anthony J. Hickey (2012). Effects of Device and Formulation on In Vitro Performance of Dry Powder Inhalers. The AAPS Journal, 14(3), -. https://europub.co.uk/articles/-A-681229