EFFECTS OF DIFFERENTINSTRUMENTATION TECHNIQUES ON ANTERIOR COLUMN AXIAL LOADING IN BOVINE SPINE MODEL: A BIOMECHANICAL STUDY
Journal Title: Journal of Turkish Spinal Surgery - Year 2008, Vol 19, Issue 2
Abstract
Objectives: The aim of this study is investigate the axial loading on vertebral body with different instrumentation techniques in bovine spine model which has a standardized biomechanical instability. Materials and Method: Anterior total corpectomy was performed to six bovine spine for standart instability model. A load cell placed at the defect site. Four different instrumentation techniques such as; (1) anterior corpus plate, (2) anterior double rod, (3) posterior short segment transpedicular screw, (4) combined anterior double rod and posterior short segment transpedicular screws were performed. Each specimen was axially loaded and the measurements of load cell at 200, 400, 600 and 800 Newton axial loads were recorded. Mann Whitney U test was used for statistical analysis. Results: Anterior load cell measurements of combined anterior plate and posterior short segment transpedicular screw applications are significantly lower than the other instrumentation techniques (p<0.05). Conclusion: Combined anterior and posterior fixation can resist more axial loads than the other instrumentation techniques in a bovine spine model.
Authors and Affiliations
İbrahim Ekrem DEVSEREN, Ömer AKÇALI, Berivan ERİK, İbrahim MUTLU
A SIGNIFICANT FIGURE IN THE ANKARA MEDICAL FACULTY PART 1: PROF. İLKER ÇETİN M.D.
The Department of Orthopedics and Traumatology of Ankara University’s School of Medicine has trained and developed many academicians in terms of almost every sub-branch of Orthopedics, from the very first day it was esta...
THE USE OF INTRAOPERATIVE AUTOTRANSFUSION İN ORTHOPAEDIC PATIENTS
The use of homologous blood transfusion should be minimized to reduce the risks of transfusion including transfer of HBV and HIV. This aim can be achieved by hypotensive anesthesia or autolog blood transfusion either by...
THE ROD-SLEEVE METHOD FOR THE TREATMENT OF THE BURST FRACTURES IN THE THORACOLUMBAR SPINE
At the Istanbul University, Istanbul Faculty of Medicine, Orthopaedics and Traumatology Department, the Rod- Sleeve method was applied to 36 burst fractures in the thoracolumbar spine of 32 cases between October 1987 and...
COMPARISON OF SEGMENTAL VERSUS HYBRID INSTRUMENTATION FOR THE SURGICAL TREATMENT OF ADOLESCENTIDIOPATHIC SCOLIOSIS
Purpose: The aim of this study is to compare the results of segmenter pediculer screw and hybrid instrumentation in adolescent idiopathic scoliosis surgery with coronal and sagittal balance, correction rates of curves...
TERATOMA OF THE SPINAL CORD: A CASE REPORT
Intradural spinal teratomas are very rare dysembriogenetic tumors. We present an intra-dural extramedullary spinal teratoma without spinal dysraphism. Poeze et al. reported 83 spinal teratomas from the literature review...