Efficacy and safety of micropulse laser trabeculoplasty for primary open angle glaucoma
Journal Title: International Journal of Ophthalmology - Year 2019, Vol 12, Issue 5
Abstract
"AIM: To evaluate the efficiency and safety of micropulse laser trabeculoplasty (MLT) for primary open angle glaucoma (POAG) patients. METHODS: Retrospective study. POAG patients undergoing MLT in Peking University Third Hospital from June 2016 to November 2017. Seventy-two eyes of 72 POAG patients were enrolled. Only one eye of each patient was treated by MLT. The intraocular pressure (IOP) before MLT and at 1d, 1, 4, 12 and 24wk and glaucoma medication before and after treatment were compared. RESULTS: The IOP was 20.6±5.9 mm Hg before MLT and 20.8±6.8 mm Hg at 2h after MTL. The IOP at 1d, 1, 4, 12 and 24wk was 17.9±4.4, 18.0±4.3, 17.5±3.4, 17.0±2.7, and 16.5±2.9 mm Hg, respectively. The IOP before and after MLT demonstrated a statistically significant difference by ANOVA analyses (F=5.797, P<0.001). Least significant difference t-tests showed there was no statistically significant difference between pre-MLT IOP within 2h after MLT (P=0.207). The statistically significant difference was confirmed between the pre-MLT IOP at 1d, 1, 4, 12 and 24wk after MLT (P=0.006, 0.009, 0.001, <0.001, <0.001, respectively). The number of glaucoma medications before MLT was 1.7±1.4 and 1.5±1.4 24wk after MLT with a significantly statistical difference (t=2.219, P=0.031) CONCLUSION: MLT is effective and safe for POAG patients. No patient experienced IOP spikes after MLT. The IOP 6mo after treatment decreased significantly with less glaucoma medication."
Authors and Affiliations
Chun Zhang
MnSOD Val16Ala polymorphism associated with retinopathy risk in diabetes: a PRISMA-compliant Meta-analysis of case-control studies
"AIM: To investigate the association of Manganese superoxide dismutase (MnSOD) Val16Ala polymorphism with diabetic retinopathy (DR). METHODS: PubMed, Embase, China National Knowledge Infrastructure, and Wanfang databases...
Ocular prosthesis incorporating IPS e-max press scleral veneer and a literature review on non-integrated ocular prosthesis
The article highlights a new method for the fabrication of an ocular prosthesis by the incorporation of a ceramic scleral veneer. The steps of fabrication include impression making, wax try-in, performing a “cut-back” on...
Long-term safety of laser in situ keratomileusis in eyes with thin corneas: 5-year follow-up
"AIM: To investigate the long term (≥5y) efficacy, predictability, and safety of laser in situ keratomileusis (LASIK) in eyes with thin corneas [central corneal thickness (CCT) <500 µm]. METHODS: A total of 339 patients...
Crosslink between lipids and acute uveitis: a lipidomic analysis
"AIM: To explore the roles of phospholipids and sphingolipids in the inflammatory process of uveitis. METHODS: Aqueous humor (AH) and the retina were obtained from endotoxin-induced uveitis (EIU) rats during the acute in...
Weighing of risk factors for penetrating keratoplasty graft failure: application of Risk Score System
"AIM: To analyze the relationship between the score obtained in the Risk Score System (RSS) proposed by Hicks et al with penetrating keratoplasty (PKP) graft failure at 1y postoperatively and among each factor in the RSS...