Efficiency of installation of turbo drive of the feed pump instead of electric drive for 200 MW power plants.

Abstract

There are 43 power generating unit with the capacity of 200 MW operate in Ukraine. Some of them for various reasons work with incomplete load The reasons for this are low fuel quality, technical condition of the boiler unit, participation in the regulating mode of the power system. Currently, for feeding water to the boiler power generating units of 200 MW use electric drive pumps (EDP). When the power generating unit is running in partial load mode, the EDP operates at constant revolutions and a prac-tically constant pressure, and the EDP output is regulated by a boiler capacity regulator (BCR), the pressure difference at which increases. At the same time, the power consumed by the EDP decreases slightly. The mode of the most economical operation of the power generating unit corresponds to the maximum opening of the BCR with a pressure drop on it of not more than 5...10 kg/cm 2 . This adjustment is possible when the feed pump is worked with a variable speed, and in this situation it is advisable to install the turbo drive of the feed pump instead of the electric drive. The purpose of this article is to analyze the efficiency of installing the turbo drive of the feed pump, to identify the advantages of the turbo drive of the feed pump, to consider the various options for including the turbo drive of the feed pump in the thermal scheme of the power generating unit. The advantages of the turbo drive of the feed pump: - the possibility of changing the output and pressure of the feed pump by regulating the number of its revolutions with a significant reduction in energy consumption; - the operational maneuverability of the unit is ensured when covering a wide range of possible loads; - the possibility of the power unit operating on sliding parameters, which, both with the adjustment of the steam distribution, leads to an increase in the electric power of the main turbine and the profitability of the power unit as a whole. Operation of the unit on sliding parameters with reduced pressure and temperature favorably affects the state of the metal, the service life and reliability of the elements of the boiler and turbine; - the possibility of providing their own needs in a pair of certain parameters with the exhaust steam of the turbo drive. At the same time, no need uneconomical reduction-cooling devices, which resulting in underproduction of electric power. Depending on the parameters of the steam before the turbo drive and behind it, the presence or absence of station consumers of the reduced steam, as well as the operation modes of the main turbine, there are several options for switching the turbo drive of the pump into the thermal scheme of the power generating unit are possible. For example, feeding the turbo drive with fresh steam from the boiler and discharging the exhaust steam into the auxiliary sewer (13 atm), supplying the turbo drive with steam from the 2nd (or 3rd) regenerative intake and discharging the exhaust steam into the flowing part of the low-pressure cylinder of the turbine, steam turbine from the 2nd (or 3rd) regenerative selection and discharge of the exhaust steam into the turbine condenser.

Authors and Affiliations

T. N. PUGACHOVA

Keywords

Related Articles

Model of asynchronous motors with a short-cooled rotor in Mathcad software.

In the article, for a specific example, the model of the asynchronous motor with short-circuited rotor in the MATHCAD software environment is considered. In compiling the model, displacement of the current in...

A method of industrial oriented software influence evaluation in manufacturing enterprises information systems.

A method of calculating the volume of data transferred through industrial data transfer network during working of SCADA/HMI-, EAM-, MES-systems and OPC-servers in industrial and office segments...

Analysis of the methods of the normalization of the specific consumption of heat and electric power in the institu-tions of the public sector.

The article describes the real situation of normalization of specific consumption of fuel and energy resources by the institutions of the public sector of the Kharkiv region. Identified shortcomings from use of the ca...

Improvement of the converter unit for a combined system of power supply of a local object with a wind gener-ator.

Combined power supply systems for local objects use renewable energy sources and are connected to an alternating current grid. Autonomous wind generators contain an uncontrolled rectifier at the generator output, conve...

Engineering and grounding parameters for equipment used to search for defects in underground cable networks.

Mine power cables are the most vulnerable and dangerous elements of underground electrical networks because of the great length and heavy duty. They account for 40% of accidents. The high number of damaged cable lines d...

Download PDF file
  • EP ID EP660791
  • DOI -
  • Views 163
  • Downloads 0

How To Cite

T. N. PUGACHOVA (2017). Efficiency of installation of turbo drive of the feed pump instead of electric drive for 200 MW power plants.. Наукові праці Донецького Національного Технічного Університету серія: Електротехніка і Енергетика, 1(1), 100-111. https://europub.co.uk/articles/-A-660791