Effect of Anthropometrical Measurements on Liver Span Using Ultrasonography

Abstract

Background: Various anthropometrical measurements may influence liver size. Aim: To study correlation of liver span according to age, sex, weight, height, and BMI. Material and Methods: The study was conducted on 100 healthy subjects aged 18-65 years. The Ultrasonographic liver span in MCL was then correlated with age, sex, height, weight, and BMI of the subjects. Results: Ultrasonographic mean liver span in males was 14.16 ± 1.32 cm while in females it was 12.79 ± 1.40 cm. Positive correlation was found with age (r=0.268; p=0.007) and weight (r=0.4767 and p<0.001) while negative with BMI (r=-0.226 and p=0.0238). Height had signifcantly high positive correlation (r=0.752; p<0.001). Conclusions: Ultrasonographic liver span had a positive correlation with age, weight, and height; while a negative correlation with BMI of the subjects was seen. Among all variables height was the major factor determining the liver span in the MCL.

Authors and Affiliations

Bhavna Singla| Department of Microbiology, Government Medical College, Patiala, Rajindra Hospital, Patiala, Punjab, India, Corresponding e-mail: jindal.bhavna@gmail.com, Tajinder Singh| Government Medical College, Patiala, Rajindra Hospital, Patiala, Punjab, India, Mohit Jain| Mohit Jain, Assistant Professor of Orthopedics, Pravana Institute of Medical Sciences, Loni, Maharashtra, India, Sejal Savani| Sejal Savani, MPH Medicine, New York University, USA, Sharad Oli| Sharad Oli, Nobel Medical College, Biratnagar, Nepal

Keywords

Related Articles

Health Education and Health Promotion Skills of Health Care Professionals Working in Family Health Centres

Preventable diseases pose a serious problem worldwide. The role of primary healthcare professionals is especially signifcant in promoting health. Aim: It is aimed to determine the health care professionals working in fa...

Coping behaviors in families with children suffering from thalassemia major and evaluating the implementation effect of nursing intervention on these behaviors

Thalassemia disease in children, make the family and especially parents faced with many challenges. Better and more effective coping behaviors in father and mother, are followed by increased quality level of the sick ch...

In Vivo effect of Lidocaine on mouse exposed to Odontobuthos Doriae Scorpion venom

Odontobuthos doriae, a native scorpion in southern tropical parts of Iran, can cause serious health threats and wide ranges of pharmacological disturbances. α-toxins in its venom cause prolongation of Na+ channels acti...

PERNICIOUS ANEMIA IN YOUNG: A CASE REPORT WITH REVIEW OF LITERATURE

Pernicious anemia (PA) is characterized by Vitamin B12 deficiency which arises due to lack of intrinsic factor as a result of autoimmune destruction of gastric body mucosa and loss of gastric parietal cells. Generally...

COLD AGGLUTININ INDUCED HEMOLYTIC ANEMIA IN A PATIENT WITH PULMONARY TUBERCULOSIS

Autoimmune hemolytic anemias (AIHA) are an uncommon group of disorders characterized by red cell destruction due to autoantibodies. Though usually idiopathic, AIHA is commonly associated with lymphoproliferative disord...

Download PDF file
  • EP ID EP12438
  • DOI -
  • Views 312
  • Downloads 14

How To Cite

Bhavna Singla, Tajinder Singh, Mohit Jain, Sejal Savani, Sharad Oli (2017). Effect of Anthropometrical Measurements on Liver Span Using Ultrasonography. International Journal of Medical Research & Health Sciences (IJMRHS), 6(9), 5-10. https://europub.co.uk/articles/-A-12438