Abstract

Application of magnesium selective electrodes to magnesium ion determination in biomedical samples has been introduced to analytical chemistry since 1990- ies. Using ion selective electrode, the ionized magnesium concentration is determined. Until this time, mainly concentration of total magnesium was determined. In this work, the importance of magnesium and its role in the human organism is shortly presented. Then, we present basics of ion selective electrodes and their application in clinical analyzers. We show exemplary applications of ionized and total magnesium concentration determination in clinical samples, such as blood serum or plasma and erythrocytes, in healthy people and in patients with various diseases. In every case, the ionized magnesium concentration in erythrocytes appears to be the most sensitive indicator of hypomagnesemia that is the pathophysiologically lowered magnesium level in organism. The knowledge of this parameter allows physicians for better diagnosis of magnesium status in human organism.

Authors and Affiliations

Magdalena Maj-Żurawska, Andrzej Lewenstam, Adam Hulanicki

Keywords

Related Articles

Badanie elektrochemicznej absorpcji wodoru w palladzie i jego stopach przy użyciu elektrod o ograniczonej objętości

The review summarizes the results of the electrochemical studies on hydrogen absorption in Pd and Pd alloys prepared in the form of thin deposits on a hydrogen -neutral matrix. This kind of electrodes, called Limited Vol...

Nanomaszyny molekularne

The work discusses the beginning of nanotechnology, mentions its creators and tells about breakthrough discoveries that contributed to its developments as a science. Next, the focus was on several of the most important n...

Zastosowanie soli chinoliniowych i pirydyniowych do oznaczania wybranych związków siarki w próbkach biologicznych

heterocyclic ring [4, 13, 23]. In analytical chemistry quinolinium and pyridinium salts such as 2-chloro-1-methylquinolinium tetrafluoroborate (CMQT) or 1-benzyl-2-chloropyridinium bromide (BCPB) perform very well as thi...

Polihistydylowe sekwencje z motywem His-tag – ich rola i biologiczne znaczenie oddziaływania z jonami metali

His-tags are specific sequences containing six to nine subsequent histydyl residues and they are used commercially in immobilized metal affinity chromatography (IMAC) as molecular ‘anchors’ that bind to a metal ion (usua...

Adenozyno-5’-o-(n-acylosulfamoilowe) pochodne jako potencjalne leki przeciwgruźlicze

Mycobacterium tuberculosis (Mtb), the etiological agent of tuberculosis (TB), is the leading bacterial cause of infectious disease mortality. The current WHOapproved treatment for TB involves a three- or four-drug regime...

Download PDF file
  • EP ID EP585162
  • DOI -
  • Views 130
  • Downloads 0

How To Cite

Magdalena Maj-Żurawska, Andrzej Lewenstam, Adam Hulanicki (2015). Elektrody jonoselektywne czułe na jony magnezowe w badaniu specjacji magnezu w organizmie ludzkim. Wiadomości Chemiczne, 69(9), 671-685. https://europub.co.uk/articles/-A-585162